background image

 

Page 2 of 24                                                                                                                                                      M7159 iss 4.4 

 

 

 

Please take your time to read this Instructions book in order to understand the safe and 
correct use of your new Bibby Scientific product. 
 
It  is  recommended  the  Responsible  Body  for  use  of  this  equipment  reads  this 
Instruction book and ensures the user(s) are suitably trained in its operation. 

 

CONTENTS 

 

 

 

Section 1 

Introduction 

Page 3 

 

 

 

Section 2 

Symbols and using this Instruction book 

Page 4 

 

 

 

Section 3  

Safety Information. 

Page 5 

 

 

 

Section 4 

Unpacking and contents 

Page 7 

 

 

 

Section 5 

Installation 

Page 8 

 

 

 

Section 6 

Environmental Protection. 

Page 9 

 

 

 

Section 7 

Product Operation. 

Page 10 

 

 

 

Section 8 

Technical Specification. 

Page 12 

 

 

 

Section 9 

Maintenance 

Page 13 

 

 

 

Section 10 

Customer Support 

Page 18 

 

 

 

Section 11 

Spares and Accessories 

Page 20 

 

 

 

Section 12 

Notes 

Page 21 

 

 

 

Section 13  

EC declaration of Conformity 

Page 24 

 

 

 

Appendix A 

Decontamination Certificate. 

Page 19 

 

©

 The copyright of this instruction book is the property of Bibby Scientific Limited. This instruction book is supplied 

by  Bibby  Scientific  Limited  on  the  express  understanding  that  it  is  to  be  used  solely  for  the  purpose  for  which  it  is 
supplied.  It may not be copied, used or disclosed to others in whole or part for any purpose except as authorised in 
writing  by  Bibby  Scientific  Limited.  Bibby  Scientific  Limited  reserves  the  right  to  alter,  change  or  modify  this 
document without prior notification.  

 

In the interest of continued development 

Bibby Scientific Limited

 

reserve the right to alter or modify 

the design and /or assembly process of their products without prior notification. 

 

This product is manufactured in Great Britian by Electrothermal, part of the Bibby Scientific Group of 
companies.  

 

Bibby Scientific Limited.

 

Beacon Road,  
Stone,  
Staffordshire ST15 0SA,  
Great Britain. 
 
Tel: +44(0)1785 812121    
Fax: +44(0)1785 810405 

 

 
 
 
 
 

 
 

Summary of Contents for Electrothermal MC242

Page 1: ...Page 1 of 24 M7159 iss 4 4 MC242 MC242X1 CONTROLLER INSTRUCTION BOOK ...

Page 2: ...claration of Conformity Page 24 Appendix A Decontamination Certificate Page 19 The copyright of this instruction book is the property of Bibby Scientific Limited This instruction book is supplied by Bibby Scientific Limited on the express understanding that it is to be used solely for the purpose for which it is supplied It may not be copied used or disclosed to others in whole or part for any pur...

Page 3: ...e loads such as Heating Mantles Heating Tapes and Cords 1 2 The MC242 is supplied with a mains output lead with an IEC socket to connect it to the resistive load 1 3 The MC242 is supplied with a rod support clamp at the rear of the controller to take a standard 12 5mm I 2 diameter rod 1 4 MC242 is a 230V AC Controller The MC242X1 is a 115V AC Controller ...

Page 4: ...one s self or other people The Responsible Body and the Operator should read and be familiar with this Instruction book in order to preserve the protection afforded by the equipment To prevent injury or equipment damage it is the manufacturer s recommendation that all persons using this equipment are suitably trained before use 2 2 Symbols Defined Caution risk of danger See note or adjacent symbol...

Page 5: ...s supply voltage is correctly earthed grounded in accordance with current area legislation Do not install or remove any heating apparatus from the controller whilst power is applied 3 2 General safe Operating Practice Always follow good laboratory practice when using this equipment Give due recognition to your company s safety and legislative health safety procedures and all associated legislation...

Page 6: ...point substances away from heating apparatus Do not operate or handle any part of this product with wet hands Do not leave this product switched on without glass sides in place for prolonged periods Keep the Mains Plug and Lead set cable away from the heating apparatus being controlled Refer to Instructions book product data label for the resistive load of equipment to ensure controller is suitabl...

Page 7: ... wired input Illustration only Contents Item Description Qty 1 MC242 Control unit 1 2 Moulded mains cord and plug set Input Note x1 variant hard wired A R 3 Instructions book this document 1 4 Moulded mains cord and socket set Output Not on 115V 1 For future reference please record your products Serial and Model Numbers Serial Number Model Number ...

Page 8: ...ure only the correct rated mains input fuses are fitted Where applicable ensure the correct mains cable fuse if fitted See Technical Information Section 8 of this Instruction book 5 5 Check the voltage on the product data label of this unit Ensure the rating conforms to your local supply If an 115V product is used in a 230V supply area then a 230 115V transformer must be installed between the 230V...

Page 9: ...er information For end users outside of the EU consult applicable regulations 6 4 This product should only be dismantled for recycling by an authorised recycling company This product and accessories must be accompanied by a completed Decontamination Certificate prior to any disposal Copies of the Certificate are available from your distributor of Bibby Scientific products or you may copy and enlar...

Page 10: ...6 Mains power on neon lamp White 7 Mantle Bunsen heaters on neon lamp Amber 8 Regulator control knob 115V illustration x1 variant 1 Mains Input Cable 2 Mains Fuse 3 Earth continuity test point 4 Mains Output IEC socket 5 Dataplate label See for correct voltage type 6 Rod support clamp 7 Mains power on neon lamp White 8 Mantle Bunsen heaters on neon lamp Amber 9 Regulator control knob Check the Dat...

Page 11: ... amber neon lamp on the controller will pulsate to show that power is being supplied to the mantel heating tape or cord etc The frequency of the pulse will increase as the regulator control knob setting is increased At maximum setting the amber neon will be continually illuminated 7 6 When your process is complete switch off the controller and disconnect it from the mains electricity supply Always...

Page 12: ...d IEC plug and lead set cable USA AZ6746 3 core earthed ground 2 meters long Moulded IEC plug and Lead set supply cord SJT VW 1 105 Replace only with equivalent cable Mains cord and moulded IEC plug and lead set cable Switzerland AZ6175 3 core earthed ground 2 meters long Moulded IEC plug and Lead set supply cord W W 05 VAS F Replace only with equivalent cable Mains cord and moulded IEC plug and l...

Page 13: ...eriodic electrical safety testing an annual test is recommended as the minimum requirement Regular inspection for damage with particular attention to the mains lead and plug set Routine cleaning of the equipment should be undertaken using a clean cloth Check the ventilation slots are clear DO NOT USE SOLVENTS FOR CLEANING ANY PART OF THIS EQUIPMENT 9 2 Replacing controller fuses MC242 230V The mai...

Page 14: ...ng the base Lift the base off 9 3 4 Disconnect the tagged wires one at a time from old and connect to the new energy regulator Refer to wiring diagram Reassemble 9 3 5 Position new energy regulator then fit and tighten the shakeproof washer and locknut 9 3 6 Replace the energy regulator control knob ensuring the flat on surface on the energy regulator spindle is aligned 9 3 7 Replace the base and ...

Page 15: ...ote a slight twisting movement may be necessary Reassemble 9 4 5 Insert the new neon ensuring the tags align with the other neon 9 4 6 Reconnect the tags 9 4 7 Replace the base and refit the two securing screws The responsible body shall check the electrical safety of the unit before further use 9 5 Replacing the Controller Output lead 9 5 1 Turn your product off and remove it from the mains suppl...

Page 16: ...ts to locate through the aperture in the back plate Note a reasonable amount of force may be required 9 5 9 Check the fitting by pulling on the output mains cable while holding the back plate 9 5 10 Locate the earth wire ring tag on the earth post and refit the stiff nut Note Only replace with rated cable type specified in section 8 1 The cable contains an earth ring and insulated connection tags ...

Page 17: ...fore using any cleaning or decontamination method the Responsible Body should check with the manufacturer the proposed method will not damage the equipment Prior to further use the Responsible Body shall check the electrical safety of the unit Only if all safety requirements are met can the unit be used again The above procedure is intended as a guide Should spillage occur with a toxic or hazardou...

Page 18: ...ain Tel 44 0 1785 812121 Fax 44 0 1785 810405 General enquiries info bibby scientific com Order enquiries sales bibby scientific com Technical support electrothermalhelp bibby scientific com www electrothermal com For the America s and Canada contact Techne Incorporated 3 Terri Lane Suite 10 Burlington NJ 08016 USA Toll free 800 225 9243Tel 609 589 2560 Fax 609 589 2571 Email labproducts techneusa...

Page 19: ...leting YES NO as applicable and by providing details in section 2 below A Blood body fluids Pathological specimens YES NO Provide details if YES B Biodegradable material that could become a hazard YES NO Provide details if YES C Other biohazard YES NO Provide details if YES D Chemical or substances hazardous to health YES NO Provide details if YES E Radioactive substances State name s and quantiti...

Page 20: ...nergy Regulator 115V M5737 1 Retort Rod AZ6751 1 Output Moulded Mains lead universal jump cord and lead set 230V M7237 1 Output Moulded Mains lead universal jump cord and lead set 115V M6288 1 Mains cord and moulded IEC plug and lead set UK 230V AC AZ9165 1 Mains cord and moulded IEC plug and lead set USA 115V AC AZ6746 1 Mains cord and moulded IEC plug and lead set Europe 230V AC AZ6747 1 Mains c...

Page 21: ...Page 21 of 24 M7159 iss 4 4 12 NOTES ...

Page 22: ...Page 22 of 24 M7159 iss 4 4 ...

Page 23: ...Page 23 of 24 M7159 iss 4 4 ...

Page 24: ...fic Limited Beacon Road Stone Staffordshire ST15 0SA Great Britain Tel 44 0 1785 812121 Fax 44 0 1785 810405 General enquiries info bibby scientific com Order enquiries sales bibby scientific com Technical support electrothermalhelp bibby scientific com www electrothermal com For the America s and Canada contact Techne Incorporated 3 Terri Lane Suite 10 Burlington NJ 08016 USA Toll free 800 225 92...

Reviews: