Technical information
15
Injectors
mm/100ø
Natural G20
130
Butane G30
77
Propane G31
77
Electrical Data
Voltage
V~
230
Frequency
Hz
50
Power consumption
W
150
Protection degree
IPX4D
External fuse rating
A
3
Internal fuse rating
A
F1---F2 3,15 AF
Flue design
Type C12 C32 C42 C52 C82
Flue pipe diameter
Coaxial
mm
60/100
Twin split pipes
mm
80
Roof
mm
80/125
Nominal heat flow rate
(A)(D)
kW
29,0
Exhaust temperature
(D)
˚
C
69
Mass flow rate
(D)
g/s
17,8
Flue gas figures
Nominal heat input
(A)(D)
kW
29,0
CO
2
content
%
6,8
O
2
content
%
8,8
CO content
ppm
52
Exhaust temperature
(D)
˚
C
69
NO
x
class
2
Weighted NO
x
ppm
92
Other specifications
Height
mm
803
Width
mm
400
Depth
mm
350
Weight (dry)
kg
42,5
Water volume in the boiler
(up to 1 bar)
l (kg)
4,1
(D)
Values refer to tests with a 1 m chimney working at the nominal heat input
IN
S
TA
LLA
TI
O
N