- 23 -
MAIN ELECTRONIC CONTROL/IGNITION P.C.B.
5
Press "A" or "B" (Figure 9.5) to confirm the value entered and
return to the list of parameters (Figure 9.8).
6 Press "A" or "B" until the LCD display shows the code
P02
,
indicating entry into “parameter P02” (Figure 9.10).
Figure 9 .10
bar
RESET
7 By using buttons "D" or "E" (Figure 9.5) it is possible to modify
the value of parameter P02 (Figure 9.11).
78
= Default
83
= Correct
Figure 9 .11
bar
RESET
8 Press "A" and hold until the LCD display shows the code
P09
,
indicating entry into “parameter P09” (Figure 9.12).
Figure 9 .12
bar
RESET
9 By using buttons "D" or "E" (Figure 9.5) it is possible to modify
the value of parameter P09 (Figure 9.13).
03
= Default
01
= Correct
Figure 9 .13
bar
RESET
10
Press "A" or "B" (Figure 9.5) to confirm the value entered and
return to the list of parameters (Figure 9.12).
11 Press "A" and hold until the LCD display shows the code
A01
, indicating entry into “parameter A01” (Figure 9.14).
Figure 9 .14
bar
RESET
12 By using buttons "D" or "E" (Figure 9.5) it is possible to modify
the value of parameter A01 (Figure 9.15).
00
= Natural gas (G20)
01
= Propane gas - LPG (G31)
Figure 9 .15
bar
RESET
13
Press "A" or "B" (Figure 9.5) to confirm the value entered and
return to the list of parameters (Figure 9.14).
14 Press "A" and hold until the LCD display shows the code
A02
, indicating entry into “parameter A02” (Figure 9.16).
Figure 9 .16
bar
RESET
15 By using buttons "D" or "E" (Figure 9.5) it is possible to modify
the value of parameter A02.
01
= high temperature (50/80°C)
02
= low temperature (25/55°C)
03
= full temperature set (25/85°C) (factory setting)
16
Press "A" or "B" (Figure 9.5) to confirm the value entered and
return to the list of parameters (Figure 9.16).
17 Press "A" and hold until the LCD display shows the code
A12
, indicating entry into “parameter A12” (Figure 9.17).
Figure 9 .17
bar
RESET
18 By using buttons "D" or "E" (Figure 9.5) it is possible to modify
the value of parameter A12 (Figure 9.18).
03
= Default
04
= Correct
Figure 9 .18
bar
RESET
19
Press "A" (Figure 9.5) to confirm the value entered and return
to the list of parameters (Figure 9.17).
20 Press "A" and hold until the LCD display shows the code
A21
, indicating entry into “parameter A21” (Figure 9.19).