- 13 -
FAULT FINDING
Figure 4 .5
bar
RESET
3 Press the "E" key to set "
1 -
-", e sucthen press "A" to confirm
the 1 and go to the next segment.
4 Press the "E" key to set "
1 9
-", then press "A" to confirm the
9 and go to the next segment.
5 Press the "E" key to set "
1 9 8
", then press "A" to confirm the
8 and go back to the list of parameters
6 Press "A" and hold until the LCD display shows the code
A51
, indicating entry into “parameter A51” (Figure 4.6).
Figure 4 .6
bar
RESET
7 By using keys "D" or "E" (Figure 4.3) it is possible to modify
the value of parameter A51 from
1
to
52
weeks (
52
= 1 year).
8
Press "A" or "B" (Figure 4.3) to confirm the value entered and
return to the list of parameters (Figure 4.6).
9 Press "B" and hold until the LCD display shows the code
A50
, indicating entry into “parameter A50” (Figure 4.7).
Figure 4 .7
bar
RESET
10 By using keys "D" or "E" (Figure 4.3) it is possible to modify
the value of parameter A51:
00
= maintenance period not activated
01
= maintenance period activated
11
Press "A" or "B" (Figure 4.3) to confirm the value entered and
return to the list of parameters (Figure 4.7).
12 Press the "F" key (Figure 4.3) to exit “programming mode”.
Summary of Contents for M275V.2024 SM
Page 2: ......
Page 49: ...49 SHORT SPARE PARTS LIST 6 2 3 4 7 8 10 9 11 12 18 19 20 13 14 15 16 17 1 5 Figure 21 1...
Page 50: ...50 NOTE...
Page 51: ......