MAIN ELECTRONIC CONTROL/IGNITION P.C.B.
9 MAIN ELECTRONIC CONTROL/IGNITION
P .C .B .
9 .1 Function
Figure 9 .1
From other boiler devices....
C.H. temperature probe NTC
D.H.W. temperature probe NTC
D.H.W. flow switch
Primary circuit pressure switch
Flue temperature probe NTC
Safety thermostat
Flame detection electrode
Room thermostat (if fitted)
Time switch (if fitted)
On the
Main electronic control/ignition
p.c.b.
......
Function control
C.H. temperature adjustment
D.H.W. temperature adjustment
Boiler reset button
(printed circuit board p.c.b.)
Inlet Information
Pump
Three way diverter valve
Gas valve
Fan
Ignition electrodes
Display indicates “E”*
*control panel electronic p.c.b.
Outlet command
The fundamental function of the
Main electronic control/ignition
p.c.b.
is that of controlling the boiler in relation to the external
needs (i.e. heating the dwelling or heating the water for D.H.W.
use) and operating in order to keep the temperature of the hy-
draulic circuits constant.
This is obviously possible within the useful power and maximum
working temperature limits foreseen.
Generally, the
Main electronic control/ignition p.c.b.
receives in-
let information coming from the boiler (the sensors) or from the
outside (printed circuit board p.c.b., room thermostat, etc.), pro-
cesses it and consequently acts with outlet commands on other
components of the boiler (Figure 9.1).
The
Main electronic control/ignition p.c.b.
is also a full sequence
ignition device and does a sequence of operations (ignition cy-
cle) which lead to the ignition of the gas at the burner.
It checks the presence of the flame during the entire period in
which it is activated and supplies the fan regulating its speed.
The
Main electronic control/ignition p.c.b.
has a safety function
and any incorrect interventions or tampering can result in condi-
tions of dangerous functioning of the boiler.
The
Main electronic control/ignition p.c.b.
can lock the function-
ing of the boiler (lock state) and stop its functioning up to the
resetting intervention. The lock-out is signalled on the display of
the printed circuit board p.c.b. and can be reset only by using the
boiler reset button placed on the control panel electronic p.c.b.
(see section "10.1 Function" on page 28).
Some components which are connected to the device can acti-
vate the lock state. The causes of a lock state could be:
• The intervention of the safety thermostat (overheat of the pri-
mary circuit).
•
The intervention of the flue temperature probe (overheat of the
combustion products).
• A fault on gas supply.
• Faulty ignition (faulty ignition electrodes, their wiring or con-
nection).
•
Faulty flame detection (faulty detection electrode, its wiring or
connection).
• Faulty condensate drainage.
• Faulty gas valve (faulty on-off operators or not electrically sup-
plied).
• Faulty
Main electronic control/ignition p.c.b
..
Other components like the primary circuit pressure switch can
temporarily stop the ignition of the burner but allow its ignition
when the cause of the intervention has stopped.
Figure 9.24 and Figure 9.25 show the sequence of the opera-
tions that are carried out at the start of every ignition cycle and
during normal functioning.