Control panel eleCtroniC p.C.b.
Constantly illuminated: boiler antifreeze
active.
Antifrostat
Constantly illuminated: (system anti-
freeze active.
siGnal displayed by the lcd
lcd
functiOn
e01
+
Lack of burner ignition on safety lockout.
e02
+
Safety thermostat intervention lockout.
e03
+
General lockout.
e04
+
Little pressure in the system or pressure
transducer disconnected.
e05
+
Faulty fan control system.
e06
+
Faulty c.h. temp. probe NTC (delivery).
e07
+
Faulty d.h.w. temp. probe NTC.
e08
+
Faulty external temp. probe NTC (with K
set).
e09
+
Faulty flue temp. probe NTC.
e10
+
Flue probe intervention lockout.
Flame detection error (An fla error
flashing number).
e12
+
Faulty c.h. temp. probe NTC (return).
e13
+
DT delivery-return > 40K.
e14
+
Faulty pump or primary temperature above
105°C.
e14
+
Absence of flow from temperature gradient
(>2K/s).
e19
+
Faulty d.h.w. temp. probe inlet.
e50
+
Lack of communication with the remote con-
nected to zone 2.
e69
+
Wiring error lockout.
e98
+
Failure of the solar controller.
e99
+
Boiler not configured.
l 01
Primary circuit temp. limit during D.h.w. op-
eration.
Boiler Stand-By, hyphens are turned on in
sequence to simulate running (antifreeze
protection activated).
lcd
functiOn
In the case of incorrect pressure the value is
visualised with a flashing symbol.
When pressure is achieved the symbol re-
mains on for 15 s and then disappears.
Flashing:
high pressure > 2.8 bar ON, 2.6 bar OFF;
intermediate pressure
0.15 < P < Pon rising
0.15 < P < (Pon-0.2) decreasing;
pressure critical
0.00 < P < 0.15 bar.
Pump activated for the post-circulation
phase (Po fl temperature flashing).
Boiler in anti-freeze phase (bP flashing +
temperature flashing).
Boiler on demand for d.h.w. power.
The d.h.w. temperature is displayed.
Boiler requesting heating power and remote
control connected.
Set c.h.
(all other symbols are disabled).
Set D.h.w.
(all other symbols are disabled).
Delayed burner ignition for setting the sys-
tem (the hourglass symbol turns on).
Boiler in chimney sweep in function.
The activation of the chimney sweep occurs
configuring the "parameter P09=01" and is
visualized:
LP = minimum d.h.w.;
hP = minimum heating;
cP = maximum heating;
dP = maximum d.h.w.;
The transition occurs with keys A (increase)
and B (decrease) d.h.w. temperature.
The writing on the display alternates.