- 34 -
INST
ALLA
TION
TECHNICAL INFORMATION
CO
2
contents - central heating
Nominal heat input
(A) (E)
kW 30,0
CO
2
content with gas G20 (range
min - max)
%
9,2 - 9,8
CO
2
content with gas G31 (range
min - max)
%
10,3 - 10,9
Minimum heat input
(A) (E)
kW 7,4
CO
2
content with gas G20 (range
min - max)
%
8,6 - 9,2
CO
2
content with gas G31 (range
min - max)
%
9,5 - 10,1
CO
2
contents - domestic hot water
Nominal heat input
(A) (E)
kW 34,9
CO
2
content with gas G20 (range
min - max)
%
9,3 - 9,9
CO
2
content with gas G31 (range
min - max)
%
10,3 - 10,9
Minimum heat input
(A) (E)
kW 7,4
CO
2
content with gas G20 (range
min - max)
%
8,6 - 9,2
CO
2
content with gas G31 (range
min - max)
%
9,5 - 10,1
Other specifi cations
Height
mm
700
Width
mm
400
Depth
mm
290
Weight (dry)
kg
38
Water volume in the boiler
(up to 1 bar)
l (kg)
2