Mounting cable relief bracket and covers

To secure heavy duty cables at the relay receptacles a cable relief 
bracket and cover are supplied with the ALFA II.

Secure the cable relief bracket to the ALFA II with the supplied 
M4x6mm screws. Insert your cable in the supplied screw terminal 
connector and insert this connector into the ppropriate relay recep-
tacle in the ALFA II. 

Secure the cables to the cable relief bracket with supplied cable 
binders.

Finally, mount the cable relief cover over the cable relief bracket and 
secure with supplied M4x45mm screw.

CONNECTIONS AND CONTROLS

AC Line

Connect the ALFA II to the AC line supply using the supplied power 
cable. The cable will be equipped with a line socket connector for 
use in the country of sale. 

The ALFA II incorporates a universal mains power supply which ac-
cepts AC line input from 100 V to 240 V.

Relays

Relays allow the option of NO (Normal Open) and the NC (Normal 
Close) for greatest flexibility. An LED for each relay is located on the 
front panel. When the LED illuminates green, it indicates the COM is 
connected to NO.

You can connect cables directly to the ALFA II using the supplied 
terminal block connectors for each relay. Use the supplied cable 
relief brackets to fix the cables with a cable tie to prevent acciden-
tal disconnection of the cables. (See section Mounting cable relief 
bracket and covers on page 6.)

If you want to connect and conveniently switch AC power for exter-
nal equipment, install the Biamp IEC Mains Adaptor (306-0015, sold 
separately) instead of the terminal block and cable relief brackets.

Biamp IEC

Mains Adaptor

Summary of Contents for IMPERA ALFA II

Page 1: ...ts that are not recommended because they may be hazardous Warning This equipment should be operated only from the included power supply To remove power from the equipment safely remove all power cords...

Page 2: ...Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause u...

Page 3: ...V equipment and makes it easy to use through the same interface and recognizable cus tom graphical user interface Create custom graphical user interfaces using the intuitive Biamp Project Designer sof...

Page 4: ...t 0 5A Connector 5 pin screw block RS 232 Baud rate 1200 115200 bit sec Data bits 7 8 Parity Even Odd None Stop bits 1 2 IR Transmit frequency 400 Hz to 500 KHz IR Learn frequency 1 KHz to 150 KHz uSD...

Page 5: ...ving on RS 232 or IR 2 Indication for Input and Output on rear panel I O 3 Relay indication and test buttons 4 Mini USB for programming 5 Input for IR learning 6 Power indication Number Description 1...

Page 6: ...erformance If installed in a closed environment forced air circulation may be needed Mounting the unit in a 19 rack The ALFA II can easily be installed in a 19 rack Due to the standard 1U height low w...

Page 7: ...cable The cable will be equipped with a line socket connector for use in the country of sale The ALFA II incorporates a universal mains power supply which ac cepts AC line input from 100 V to 240 V R...

Page 8: ...d as inputs the applied voltage must be below 1 VDC to be accepted as LOW and above 4 VDC but below 24 VDC to be accepted as HIGH The inputs are default HIGH and must be con nected to ground in order...

Page 9: ...s the system into the local area network There are two LEDs on the connector with the following indication Factory default IP settings is IP address 192 168 254 253 Subnet 255 255 255 0 10 100Mbit Aut...

Page 10: ...ec before reconnecting the power again No project found on the control system Try to upload the project again If the problem persists after several successful uploads contact Biamp or your local distr...

Page 11: ...amp All rights are reserved No third party is allowed access to content information or data in this manual without Biamp express written consent CHANGES Biamp reserve the right to change the specifica...

Reviews: