Page 4                                                                 IV6-LAU Instructions                                                              I SERIES

LIGHT ARRAY FRAME ADAPTER U-BRACKET 

The IV6-LAU 

must

 be used with the IV6-LAF-PBB Array Frame. It is designed 

to support a variety of ancillary array mounting configurations and as a tool to 

integrate IV6 arrays with I SERIES BalancePoint™ Flyware and other 3rd party 

mounting systems. 

Before assembly:

 The IV6-LAU U-Bracket must be used with the IV6-LAF-PBB 

to integrate with an IV6 array. Determine tilt angle and approximate center of 

balance of the array for placement on the light array frame.  

1.

  Attach  the  U-Bracket  to  the  IV6-LAF  as  shown  (LAU-1).  Insert  bolts  in  the 

"pivot" position first (see below) and then secure desired angle with the other 

bolt. There is a slightly different connection for downfill applications - see LAU 

Application #5.  

Note:

 In close surface mount applications, it is easier to mount the U-Bracket to the surface before 

adding the IV6-LAF-PBB frame and loudspeakers. 

IV6-LAU
LAU:

 Light Array U-Bracket (1)

Hardware:

Qty

Code

Description

4

HHB-F 10.9 Flanged Hex Head 

Bolts

4

HN-F Flanged Nuts

Kit Weight:

 13.5 lbs (6.1 kg)

Working Load Limit: 

500 lbs (226.8 kg)

 

 

(10:1 safety factor)

1

LAU-1.

 Attach the U-bracket to the frame at the desired angle, centered around 

the specified pin point# from EASE® Focus 3

HN-F

HHB-F

Rear

Front

Parts:

LAU

Center hole - for downfire applications 

only - see Application #5 for connection 

detail

15° tilt

10° tilt

Side view, 0° tilt

Pivot position

Pivot position

IMPORTANT:

  When  used  with 

the IV6-LAF-PBB to hold a 

downfill  loudspeaker  at  the  bottom  of 

an array, the weight of the added 

elements must be considered when 

calculating the  SWL of the array.

WARNING: 

For safety reasons, 

for the applications listed on the 

next page, the center of mass of the 

array 

must

 be located directly beneath 

the IV6-LAF-PBB Frame. If the center 

of mass is located behind the array 

frame, it may result in an unsafe rigging 

condition.

Summary of Contents for COMMUNITY I Series

Page 1: ...complete set of instructions including all of the IV6 indoor rigging frames accessories and information is available on the Biamp website here IMPORTANT The Instructions and illustrations in this man...

Page 2: ...each unit after it has been removed from the packaging as damage could occur during shipping Please note that once the shipment has left your dealer or the Biamp factory the responsibility for damage...

Page 3: ...tes in real time as an array is built and aimed Refer to the IV6 System Design and Installation Manual for instructions and explanations about system design with our custom VenuePolar module in EASE F...

Page 4: ...U Bracket to the surface before adding the IV6 LAF PBB frame and loudspeakers IV6 LAU LAU Light Array U Bracket 1 Hardware Qty Code Description 4 HHB F 10 9 Flanged Hex Head Bolts 4 HN F Flanged Nuts...

Page 5: ...ERIES fill speakers to the left and right The IAF55 may also be combined with the SBR54 For this application the IV6 LAU must be bolted to the IV6 LAF PBB in the 0 position IMPORTANT No more than thre...

Page 6: ...by the installer Note Adding any elements IV6 LAF PBB IV6 LAU and a loudspeaker at the bottom of an array will change the overall weight and potentially the COG thus changing the array hang point Alwa...

Page 7: ...LACES 13 09 332 6 50 12 6 CL IV6 LAU WEIGHTS LOUDSPEAKERS includes 1 pair splay brackets Indoor lbs kg Outdoor WR lbs kg IV6 1122 05 77 3 35 1 62 5 28 3 IV6 1122 15 73 5 33 3 59 1 26 8 IV6 118S 132 9...

Page 8: ...s manual was complete and accurate when printed However due to ongoing technical advances changes or modifications may have occurred that are not covered in this manual The latest version is available...

Reviews: