7
APPLICATIONS
25 watts
class 2 wiring
50/60 Hz
~
27V
8
logic inputs
7
6
5
4
3
2
1
line outputs
CobraNet
TM
connections only
secondary
U.S. pat. no. 4,922,536
green: in use
green: link/act
orange: conductor
red: fault
LEDs
primary
1 2 3
4 5 6
7 8
MADE IN U.S.A.
BIAMP SYSTEMS
Portland, Oregon
an affiliate of Rauland-Borg Corp.
8 out
Audia
EXPO
Court C
recorder
Court D
recorder
25 watts
class 2 wiring
50/60 Hz
~
27V
8
logic inputs
7
6
5
4
3
2
1
line outputs
CobraNet
TM
connections only
secondary
U.S. pat. no. 4,922,536
green: in use
green: link/act
orange: conductor
red: fault
LEDs
primary
1 2 3
4 5 6
7 8
MADE IN U.S.A.
BIAMP SYSTEMS
Portland, Oregon
an affiliate of Rauland-Borg Corp.
8 out
Audia
EXPO
Court A
recorder
Court B
recorder
EtherNet Switch
CobraNet
&
Ethernet
Courtrooms A~D
hearing assist
Courtroom A mics
Serial Control Port
100-240V
~
50/60Hz
110 Watts
CobraNet
TM
connections only
secondary
U.S. pat. no. 4,922,536
green: in use
green: link/act
orange: conductor
red: fault
LEDs
primary
link
Remote Control Bus
BLACK connectors = OUTPUTS
GREEN connectors = INPUTS
24VDC
1.5A
term
hi lo
UL
R
C
US
Ethernet
MADE IN U.S.A.
BIAMP SYSTEMS
Portland, Oregon
an affiliate of Rauland-Borg Corp.
CAUTION
RISK OF ELECTRICAL SHOCK.
DO NOT OPEN.
52SJ
LISTED
In 1
In 2
Out 23
Out 24
In 3
In 4
Out 21
Out 22
In 5
In 6
Out 19
Out 20
In 7
In 8
Out 17
Out 18
In 9
In 10
Out 15
Out 16
In 11
In 12
Out 13
Out 14
In 13
In 14
Out 11
Out 12
In 15
In 16
Out 9
Out 10
In 17
In 18
Out 7
Out 8
In 19
In 20
Out 5
Out 6
In 21
In 22
Out 3
Out 4
In 23
In 24
Out 1
Out 2
ORANGE connectors = AEC INPUTS
Audia
FLEX
20x4 CM
Courtroom B mics
Courtroom C mics
Serial Control Port
100-240V
~
50/60Hz
110 Watts
CobraNet
TM
connections only
secondary
U.S. pat. no. 4,922,536
green: in use
green: link/act
orange: conductor
red: fault
LEDs
primary
link
Remote Control Bus
BLACK connectors = OUTPUTS
GREEN connectors = INPUTS
24VDC
1.5A
term
hi lo
UL
R
C
US
Ethernet
MADE IN U.S.A.
BIAMP SYSTEMS
Portland, Oregon
an affiliate of Rauland-Borg Corp.
CAUTION
RISK OF ELECTRICAL SHOCK.
DO NOT OPEN.
52SJ
LISTED
In 1
In 2
Out 23
Out 24
In 3
In 4
Out 21
Out 22
In 5
In 6
Out 19
Out 20
In 7
In 8
Out 17
Out 18
In 9
In 10
Out 15
Out 16
In 11
In 12
Out 13
Out 14
In 13
In 14
Out 11
Out 12
In 15
In 16
Out 9
Out 10
In 17
In 18
Out 7
Out 8
In 19
In 20
Out 5
Out 6
In 21
In 22
Out 3
Out 4
In 23
In 24
Out 1
Out 2
ORANGE connectors = AEC INPUTS
Audia
FLEX
20x4 CM
Courtroom D mics
FU
SE
FU
SE
O
2
1
1
2
outputs
level
signal / peak
signal / peak
level
input
input
4
3
3
4
outputs
level
signal / peak
signal / peak
level
input
input
6
5
Class 2 Wiring
5
6
outputs
level
signal / peak
signal / peak
level
input
input
8
7
7
8
outputs
remote control
level
CAUTION:
Risk of fire -
replace fuse only
with same type
F 10 A H 250 V
115V
~
50/60Hz
900 Watts
signal / peak
signal / peak
level
input
input
MCA 8050
BIAMP SYSTEMS
an affiliate of Rauland Borg Corp.
MADE IN U.S.A.
HPF
HPF
OFF
OFF
OFF
BRIDGE
HPF
HPF
OFF
OFF
OFF
BRIDGE
HPF
HPF
OFF
OFF
OFF
BRIDGE
HPF
HPF
OFF
OFF
OFF
BRIDGE
CAUTION
RISK OF ELECTRICAL SHOCK.
DO NOT OPEN.
52SJ
UL
R
LISTED
C
US
MCA8050
Courtroom A
speakers
Courtroom B
speakers
Courtroom C
speakers
Courtroom D
speakers
remote control options:
Volume 8
,
Select 8
,
Volume/Select 8
,
Logic Box
(volume, override,
side-bar, masking,
muting, etc.)
remote control option:
switch assignment of
courtrooms/recorders
remote control option:
switch assignment of
courtrooms/recorders
Summary of Contents for Audia EXPI
Page 2: ...print update September 7 2005 blank ...
Page 17: ...15 ...
Page 18: ...16 ...
Page 19: ...17 ...
Page 20: ...18 ...