17
APPLICATIONS
Zone Paging with Background Music & Emergency Override
Programming of the PMX84 for this application can be done by simply opening & downloading a file (page1b.pmx) during Configuration.
This application is identical to the application on the previous page, except that an emergency override signal has been added. The
emergency override signal is connected to Input 8 of the PMX84, and an emergency override switch (or contact-closure) is connected
between the Override terminal and the adjacent ground (
ý
) on the PMX84. Override is programmed to assign Input 8 to Outputs A~D.
Override maintains a higher priority than any of the Logic Inputs. When Override is activated (shorted to ground), all paging & background
music assignments will be shut off and the emergency override signal will be applied to all outputs. When Override is released (no longer
shorted to ground), the PMX84 will automatically revert to its previous settings, and normal operation. The emergency override signal may
be paging, an alarm, or a siren. If no emergency override signal is connected to Input 8 of the PMX84, the Override terminal will still
provide an override function. Under these circumstances, Override will still shut off all paging & background music assignments, but no
emergency signal will be applied to the outputs.
in
patch
pad
in
patch
pad
in
patch
pad
in
patch
pad
in
patch
pad
in
patch
pad
in
patch
pad
in
patch
pad
main
patch
main stack
DC out
1
2
3
4
5
6
7
8
E17934
±12VDC 15W
Class 2
main out
EX
patch
expansion
input
patch
expansion
input
outputs
inputs
remote inputs
1
2
3
4
gnd
IR2
IR3
gnd
IR2
IR3
gnd
IR2
IR3
gnd
IR2
IR3
logic outputs
logic inputs
serial port
~27V 15VA
50/60 Hz
Class 2 wiring
+10
+10
+10
+10
MADE IN U.S.A.
BIAMP SYSTEMS
Portland, Oregon
an affiliate of Rauland-Borg Corp.
level
5
level
6
level
7
level
8
level
C
level
D
patch
expansion
input
patch
expansion
input
+10
+10
+10
+10
level
1
level
2
level
3
level
4
level
A
level
B
override
PMX link
ADVANTAGE D60EQ
MADE IN U.S.A.
115V
*
E
S
U
F
*
E
S
F
*
E
S
U
F
115/230 VAC
50/60 Hz 160 Watts
115V: 2A SB fuse
230V: 1A SB fuse
common
Ω
autoformer
input
Ω
70V
100V
4
8
+ input
- input
gnd
ADVANTAGE D60EQ
MADE IN U.S.A.
115V
*
E
S
U
F
*
E
S
F
*
E
S
U
F
115/230 VAC
50/60 Hz 160 Watts
115V: 2A SB fuse
230V: 1A SB fuse
common
Ω
autoformer
input
Ω
70V
100V
4
8
+ input
- input
gnd
ADVANTAGE D60EQ
MADE IN U.S.A.
115V
*
E
S
U
F
*
E
S
F
*
E
S
U
F
115/230 VAC
50/60 Hz 160 Watts
115V: 2A SB fuse
230V: 1A SB fuse
common
Ω
autoformer
input
Ω
70V
100V
4
8
+ input
- input
gnd
ADVANTAGE D60EQ
MADE IN U.S.A.
115V
*
E
S
U
F
*
E
S
F
*
E
S
U
F
115/230 VAC
50/60 Hz 160 Watts
115V: 2A SB fuse
230V: 1A SB fuse
common
Ω
autoformer
input
Ω
70V
100V
4
8
+ input
- input
gnd
PMX84
D60EQ
(Zone 4)
D60EQ
(Zone 2)
D60EQ
(Zone 3)
D60EQ
(Zone 1)
from
paging
station
switches
from
emergency
override
switch
emergency
override
signal
background
music
Zone 4
paging
station
Zone 3
paging
station
Zone 2
paging
station
Zone 1
paging
station
master
paging
station
Master
1 2 3 4
5 6 7 8
9 10 11 12
13 14 15 16
Zone 1
Zone 2
Zone 3
Zone 4
Logic Inputs
with
priority grouping
All-Call
Zone 1
Zone 2
Zone 3
Zone 4
Zone 1
page
music
Zone 2
page
music
Zone 3
page
music
Zone 4
page
music
paging stations
with
routing switches