BI RDP-12 Quick Start Manual Download Page 4

Spiral Stack Cap

Typical Spiral Pipe Section

Typical Flange Connection

(gasket & bolt kit required)

Spiral Pipe Tee

RDP-12 Unit

Pressurized Building

Spiral Pipe Tee

Custom Length Spiral

Building & Stack Slabs

Grade

Model RDP-12 Unit Accessories

Housing Dimensions

Typical Installations

Wall Mount

Bebco Industries, Incorporated            Environmental Control Units Division          600 Gulf Freeway, Texas City Texas 77591      Phn:  (409) 935-5743

Roof Mount

EMERGENCY REMOTE CONTROL INPUTS

ESD-IS-RM

Intrinsic Safe ESD

ECO-IS-RM

Intrinsic Safe ECO

ESD/ECO-IS-RM

Intrinsic Safe ESD/ECO

ESD/ECO-HW-RM

Hard Wire ESD/ECO

REMOTE ALARM BEACONS AND HORNS

RAB-1

Division 1 Remote Alarm Beacon

RAB-2

Division 2 Remote Alarm Beacon

RAH

Division 1 Remote Alarm Horn

WARNING NAMEPLATES

BPCN-1

Building Pressurization Caution

SDWN-1

Sealed Door Warning

INSTALLATION & OPERATION MANUAL

RDP-12-IOM

Installation & Operation Manual

GALVANIZED OR STAINLESS STEEL SPIRAL PIPE

SP-12-120

10' Flanged Stack Section

SC-12

Flanged & Screened Rain Cap

ST-12

Flanged Tee w/ Coupler

SN-12

Flanged Elbow w/ Coupler

BC-12

Blind Flange Cover Plate

GK-12

Flange Gasket & Bolt Kit

SPIRAL PIPE STACK & GUY WIRE ANCHOR KITS

SPAK-12

Spiral Pipe Anchor Bolt Kit

EAGK-40-1216

Earth Anchor Guy Wire Kit

CAGK-40-1216

Concrete Anch. Guy Wire Kit

GAL. OR S.S. FREE STANDING RIGID PIPE STACKS

RP-12-25

25' 10 Ga Rigid Pipe Stack

RPAK-12

Rigid Pipe Anchor Bolt Kit

ADDITIONAL ITEMS

FDK-12-300

25' Flexible Duct Intake Kit

GAS DETECTOR SYSTEMS

CGDM-100

Combustible Gas Monitor

CGDS-100

Combustible Gas Sensor

HGDM-100

Hydrogen Sulfide Monitor

HGDS-100

Hydrogen Sulfide Sensor

OGDM-100

Oxygen Deficiency Monitor

OGDS-100

Oxygen Deficiency Sensor

GDPS-100

24 VDC Monitor Power Supply

GDSB-1216

Sensor Stack Mount Bracket

REMOTE MOUNT DISCHARGE COMPONENTS

ADGA-12

Adj. Discharge Grill Assembly

DE-12

Discharge Extension

DN-12

Discharge Ninety

DCF-12

Discharge Curb Flange

10.75"

6.5"

9.5"

1 8 "

Control Enclosure

Front View

(Discharge)

Front View

(Intake)

16.25"

8.125"

8.125"

12.25" O.D.

TYP 3

0.25" O.D.

TYP.8

90° max.

16.25"

90° max.

1.3125"

1.3125"

13.625"

16.25"

44.875"

36.9375"

8.125"

7"

3 2 "

0.75"

11.125"

1 5 "

3 / 4 "

FPT

Side View

44.875"

7"

3 2 "

1.6875"

1.6875"

12.875"

Top View

IMPORTANT NOTES

All specifications subject to change without notice.
Warranty & Liability policies available upon request.

The simplified installation diagrams to the left are
shown without guy wire or structural support systems,
for the purpose of maintaining diagram clarity.

Installer must recognize the need for adequate stack
guy wire or structural support systems as well as
foundation anchoring systems.  Installer assumes
all liability for the installation and integrity of said
systems, wherein design considerations should
ensure that stack guy wire or structural support
systems are capable of withstanding local inclement
weather conditions.

FOUR (4) VIBRATION DAMPENING MOUNTS WITH

SCREWS, ONE (1) BPCN-1 NAMEPLATE & ONE (1)

INSTALLATION & OPERATION MANUAL

PROVIDED WITH EACH UNIT

Model Number Designations

                                         RDP  -  12  -  D1  -  GS

Series Model Number
Remote Mount Dual Blower
Building Pressurization Unit

Unit Size
12

- 12" Diameter Fan Blades

Division Rating
D1

- Division 1

D2

- Division 2

Housing Material
GS

- 14 Ga Galvanized Steel w/ White Paint Finish

SS

- 14 Ga Stainless Steel w/ White Paint Finish

Local Sales Representative

Summary of Contents for RDP-12

Page 1: ... a local disconnect switch connected ahead of building power or connected to a separate power source The unit is started by closing the building door and placing the secondary fan switch in the automatic position and the primary fan switch in the on position The primary fan then engages to regulate air flow and maintainasafepressure Whenthedoorisopened pressure will fall below the alarm setpoint T...

Page 2: ...tedbuilding Inaddition thehousingcanbesupplied with an optional emergency remote control junction box for ECO or ESD IS barrier applications Theblowerhousingisfittedwithprimaryandsecondary fans mounted in a compact in line arrangement with the secondary fan mounted directly behind the primary fan Each motor is connected with approved MI mineral insulated cabletoseparatedisconnectswitchesmounted ex...

Page 3: ... HW Hard Wiring Selection of this option requires the use of conduit seals and wiring approved for the location IS Intrinsically Safe Selection of this option allows use of intrinsically safe cabling approved for the location NOTE Loops are self powered 5 VDC 20 ma signals regardless of wiring method selection Signals must be maintained independently by normally closedswitchestopreventshutdownorov...

Page 4: ...GDM 100 Hydrogen Sulfide Monitor HGDS 100 Hydrogen Sulfide Sensor OGDM 100 Oxygen Deficiency Monitor OGDS 100 Oxygen Deficiency Sensor GDPS 100 24 VDC Monitor Power Supply GDSB 1216 Sensor Stack Mount Bracket REMOTE MOUNT DISCHARGE COMPONENTS ADGA 12 Adj Discharge Grill Assembly DE 12 Discharge Extension DN 12 Discharge Ninety DCF 12 Discharge Curb Flange 10 75 6 5 9 5 18 Control Enclosure Front V...

Reviews: