Unit Specifications

Shipping Dimensions:

28" h x 28" w x 70" d

Shipping Weight (Lbs):

360

Operating Temp Range:

-40

°

 F - 120

°

 F

Power Requirements:

208 / 240 VAC 1Ø, 20 A

Safe Pressure Setpoint:

0.25" - field adjustable

Alarm Setpoint:

0.15" - field adjustable

Average CFM:

* 65.24.

Maximum CFM:

1370 feet/min.

Normal Sound Level:

** 60 db min. / 70 db max.

Fresh Air Intake:

12" Diameter

Field Wiring Conduit Entries:

3/4" FPT

Alarm Contact Rating:

15 Amps @ 120 VAC

Division 1 Unit Motors:

Rated Cl. I, Div. 1, Gr. C & D

Division 2 Unit Motors:

Rated Cl. I, Div. 2, Gr. C & D

Primary Motor:

3Ø Inverter Duty, T3, 100 Hz

Secondary Motor:

1Ø Perm. Split Cap., T3, 60 Hz

Primary Motor RPM:

3000 Max.

Secondary Motor RPM:

1725 Max.

* Average CFM through a 21 square feet opening

** Normal sound level tested in acoustic sound chamber

with primary fan engaged and door sealed

Material Specifications

NEMA 4 Blower Housing:

* Painted 14 Ga Galv. Steel

NEMA 4X Blower Housing:

*Painted 14 Ga 316 SS

Fan Venturis:

Painted Carbon Steel

Fan Blades:

Nonsparking Alum.

Pressure Gauge:

Alum. w / Enamel Finish

Tube Fittings:

316 SS & Nylon

Unit & Device Nameplates:

Silkscreened Lexan

®

Model Number Nameplate:

Silkscreened SS

Cover Plate Fasteners:

SS Screws & Bolts

Access Door Fasteners:

Cast Zinc Body / Zinc Bolt

Elect. Enclosures & Fittings:

Cast Zinc & Aluminum

Electrical Wiring:

Brass MI Cable & Fittings

w/ PVC Jacket

* Paint Finish Specifications:
2 mil epoxy primer & 2 mil white textured urethane finish

Lexan

®

 is a registered trademark of the General Electric Corporation

Mechanical Description

The body of Model RDP-12 is a seal-welded NEMA 4 or

4X blower housing that features one (1) full size access
door, three (3) intake openings, and two (2) opening
covers.  The housing is designed for remote mounting in
combination with Bebco Models ADGA, DCF, DE and/or
DN ductwork for installation on the wall or roof of the
protected building.  In addition, the housing can be supplied
with an optional emergency remote control junction box
for ECO or ESD-IS barrier applications.

The blower housing is fitted with primary and secondary

fans mounted in a compact in-line arrangement with the
secondary fan mounted directly behind the primary fan.
Each motor is connected with approved MI (mineral
insulated) cable to separate disconnect switches mounted
external to the blower housing.  The explosion proof
control enclosure contains a variable speed drive, a VFD
interface card and an array of control switches and
indicators.  The explosion proof control enclosure can be
mounted on any flat wall surface inside or outside of the
protected building.  A 4" building pressure indicator,
scaled to inches of water and color coded to indicate low,
high and safe building pressures, is mounted above the
explosion proof control enclosure on a stainless steel
plate.  The building pressure indicator features a 1/4" tube
fitting and sintered vent for references of building and
atmospheric pressures.

Intake Stack

Connection

Intake Stack

Connection

Gasket

Door Hinge

Mounting

Bracket

Blower Housing

Body

Door Frame

Gasket

Secondary Fan

Motor

Secondary Fan

Motor Wiring

Intake Stack

Connection w/ Blind

Cover Plate

Primary Fan

Motor

Primary Fan

Motor Wiring

Factory Installed

Primary &

Secondary Fan

Motor Disconnect

Switches, Explosion

Proof Fittings,

Conduit & Wiring

Note: Fan

disconnects can be

installed on opposite

side if requested at

time of order

Primary

Fan Engaged

Indicator

Primary

Fan Control

Switch

Secondary

Fan Control

Switch

Pressure Loss

Alarm Indicator

Control Enclosure

face view with door closed

Blower Housing

top view with door removed

Building

Pressure

Indicator

Building

Pressure

Indicator

Mounting

Bracket

Alarm System

Bypass Control

Switch

Control Enclosure

rear view

Building

Pressure

Indicator

Low Port

Flame Arrestor

High Port

Flame Arrestor

Control

Enclosure

Explosion Proof

Housing

Building

Pressure

Connection Port

(High Port)

Atmospheric

Pressure

Connection Port

(Low Port)

Control

Enclosure

Mounting Foot

(typical 4)

Summary of Contents for RDP-12

Page 1: ... a local disconnect switch connected ahead of building power or connected to a separate power source The unit is started by closing the building door and placing the secondary fan switch in the automatic position and the primary fan switch in the on position The primary fan then engages to regulate air flow and maintainasafepressure Whenthedoorisopened pressure will fall below the alarm setpoint T...

Page 2: ...tedbuilding Inaddition thehousingcanbesupplied with an optional emergency remote control junction box for ECO or ESD IS barrier applications Theblowerhousingisfittedwithprimaryandsecondary fans mounted in a compact in line arrangement with the secondary fan mounted directly behind the primary fan Each motor is connected with approved MI mineral insulated cabletoseparatedisconnectswitchesmounted ex...

Page 3: ... HW Hard Wiring Selection of this option requires the use of conduit seals and wiring approved for the location IS Intrinsically Safe Selection of this option allows use of intrinsically safe cabling approved for the location NOTE Loops are self powered 5 VDC 20 ma signals regardless of wiring method selection Signals must be maintained independently by normally closedswitchestopreventshutdownorov...

Page 4: ...GDM 100 Hydrogen Sulfide Monitor HGDS 100 Hydrogen Sulfide Sensor OGDM 100 Oxygen Deficiency Monitor OGDS 100 Oxygen Deficiency Sensor GDPS 100 24 VDC Monitor Power Supply GDSB 1216 Sensor Stack Mount Bracket REMOTE MOUNT DISCHARGE COMPONENTS ADGA 12 Adj Discharge Grill Assembly DE 12 Discharge Extension DN 12 Discharge Ninety DCF 12 Discharge Curb Flange 10 75 6 5 9 5 18 Control Enclosure Front V...

Reviews: