5 Equipment Check and Troubleshooting
56 / 64
Note
:
The PoE port o f Po E Power M ode co nnects with the equipment primary
port.
The equipment power is supplied by
Ethernet cable, so the excessive long cable
causes voltage drop, which will resulted in inadequate power supply and a bnormal
work. Within 40 meters can ensure a good working status, the crystal point should
conform to T568B sta ndard, wrong line ord er will result in abnormal power supply,
and even burn down the equipment or power source.
5. When c onfigure BXM2/5 ens ure the PC local connection is opened. Set the PC
local connection IP address is 19 2.168.1.100, ensure BXM2/5 network and PC are
in
the same network segment
, BXM2/5 default IP is 192.168.1.1
,
default password is
admin. Correctly configure IP address as required, as shown in the figure below
:
Figure 97 Set IP Address