1
3
2
4
130mm
Cable
entry
95mm
Ensure the supplied caps are fitted over installation
screws to maintain IP rating
Ensure supplied cord grip is fitted on incoming power
cable if using bottom cable entry location
Ensure 3-pole power connector is fully inserted,
then clip power connector into the base
Ensure 4-pole output connector is fully inserted,
then tuck into the base on the left side
Use included hole template to drill fixing holes
Ensure correct polarity when making
incoming power connections
L E N
5
7
6
8
For dynamic load balancing, ensure connections are made