INSTALLATION MANUAL
17.2) TABLE A: DIP SWITCH
DIP
Default
Definition
Cross out
setting
used
Description
DIP 1
ON
TCA- Automatic
closing time.
ON
Automatic closing ON.
OFF
Automatic closing OFF.
DIP 2
ON
FCH- Photocells.
ON
Photocells active during closing only.
OFF
Photocells active during closing and opening.
DIP 3
OFF
BLI - Block Pulses.
ON
START commands not accepted during opening.
OFF
START commands accepted during opening.
DIP 4
OFF
3P/4P - 3 steps or 4
steps.
ON
Switches to 3-step logic.
OFF
Switches to 4-step logic.
DIP 5
OFF
CODE FIX - Fixed code.
ON
Activates built-in receiver in fixed-code mode.
OFF
Activates built-in receiver in rolling-code mode.
DIP 6
OFF
RADIO LEARN -
Transmitter program-
ming.
ON
Enables wireless memorizing of transmitters (REPLAY, CLONI,)
OFF
Wireless memorizing disabled: wireless learning of any remote control disabled (including
CLONI and REPLAY).
DIP 7
OFF
SCA- Gate open light
or 2nd radio channel.
ON
Activates relay output as 2nd radio channel.
OFF
Activates relay output in Gate open light mode.
DIP 8
OFF
FAST CLOSE
ON
Closes barrier after the photocells are cleared before waiting for the set TCA to elapse.
OFF
Command not enabled.
18
-
MOOVI 30-60 - ALPHA BOM
D811997 00100_02