background image

COMPASS 485/232

COMPASS 485/232

ACCESS CONTROL SYSTEM

ACCESS CONTROL SYSTEM

D811320_02

18

Fig. 3

F0,1A

T

DIP SWITCH

1 2

3

6

5

4

1 2 3 4 5 6 7 8

7

8

9

10

11

12

13

14

15

16

17

18

A

L N
230V

DOOR ALARM

B

COM

OPEN

DOOR

+12V=

D1

-

12V=

LED A

LED B

COMPASS

485

COMPASS

485

COMPASS

READER 2

+12V=

D1

-

12V=

LED A

LED B

COMPASS

READER 1

NO

COM

NC

NO

COM

ON
OFF

COMPASS

485

COMPASS-READER

6 5 4 3 2 1

+1

2V=

D1 D¯

-

LED

B

LED

A

JP1
3-4

Rel Apertura Porta - Door Opening Relay

Relais Ouverture Porte - TŸršffnungsrelais

RelŽ Apertura Puerta - RelŽ de Abertura da Porta
6-7-8

Rel Allarme - Alarm Relay

Relais Alarme- Alarmrelais

RelŽ Alarma - RelŽ de alarme

JP1a

JP1b

Summary of Contents for Compass-485

Page 1: ...COMPASS 485 232 D811320 26 11 01 Vers 02 CONTROL UNIT SERIAL CONVERTER ...

Page 2: ... of Compass 485 IP20 Protection level of Compass 232 IP20 Rated temperature 20 C 60 C Opening time from 1 to 25 5 secs No of cards that can be memorised up to 6 000 The level of protection of the casing becomes IP55 when a special accessory is used which can be supplied on request Utilise only connections suitable to the dimensions of the container and the diameter of the cable 3 ASSEMBLY Fig 2 Af...

Page 3: ...tion is required the Led turns to yellow Card deactivation Show the Master Card to the reader the Led will flash changing from red to green continuously followed by the card for which access deactivation is required the Led turns to yellow If it becomes necessary to deactivate a card that has been mislaid there are two ways of doing so If the system is controlled by Securbase and the card code is ...

Page 4: ...on By installing the additional COMPASS READER 485 unit at the exit the user is obliged to exit before being allowed to re enter Real time display of access status Real time display of data regarding the card s owner Setting of the parameters related to all of the connected readers Recording of access events with possibility of subsequent tracing and printing Control of up to 20 COMPASS 485 units ...

Page 5: ...D811320_02 ACCESS CONTROL SYSTEM ACCESS CONTROL SYSTEM COMPASS 485 232 COMPASS 485 232 17 Fig 2 Fig 1 110 147 34 ...

Page 6: ...12V D1 12V D LED A LED B COMPASS 485 COMPASS 485 COMPASS READER 2 12V D1 12V D LED A LED B COMPASS READER 1 NO COM NC NO COM ON OFF COMPASS 485 COMPASS READER 6 5 4 3 2 1 12 V D1 D LED B LED A JP1 3 4 Rel Apertura Porta Door Opening Relay Relais Ouverture Porte T r ffnungsrelais Rel Apertura Puerta Rel de Abertura da Porta 6 7 8 Rel Allarme Alarm Relay Relais Alarme Alarmrelais Rel Alarma Rel de a...

Page 7: ...COMPASS 485 2 COMPASS 485 3 COMPASS 485 19 COMPASS READER 2 COMPASS READER 1 COMPASS READER 0 COMPASS READER 3 COMPASS READER 19 COMPASS 232 SecurBase COMPASS 485 2 8 9 10 11 12 13 14 15 16 17 18 8 9 10 11 12 13 14 15 16 17 18 8 9 10 11 12 13 14 15 16 17 18 8 9 10 11 12 13 14 15 16 17 18 COMPASS 485 X COMPASS 232 MAX 500 m 6x0 5mm MAX 5 m 6x0 5mm MAX 5 m 6x0 5mm MAX 5 m 6x0 5mm MAX 5 m 6x0 5mm MAX...

Page 8: ... 9 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 ID 10 ID 11 ID 12 ID 13 ID 14 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 ID 15 ID 16 ID 17 ID 18 ID 19 RS 232 COMPASS 232 SecurBase COMPASS 485 1 8 9 10 11 12 13 14 15 16 17 18 8 9 10 11 12 13 14 15 16 17 18 8 9 10 11 12 13 14 15 16 17 18 COMPASS 485 2 COMPASS 485 X COM SECURBASE...