4.3 Storage and maintenance

4.3.1 The equipment should be handled carfully and lightly. Be sure that it is far from the vibration , 
and install or keep in a cool, dry and ventilated place.
4.3.2 Don’t store the machine together with the articles that are combustible, poisonous, caustic, 
and explosive.

4.3.3 This equipment should be stored in a room where th e relative humidity is ≤80%, 

atmospheric pressure is 50kPa to 106kPa, and the temperature is -10

O

C to +50

O

C.

4.3.4  If it is has not been used a long time, please ensure the machine gets through to the power 

and water once per month for five minutes.

4.4 Transportation

4.4.1 Excessive impact and shake should be prevented in transportation. Lay it carefully and lightly 
and don’t invert it.
4.4.2 Don’t put it together with dangerous goods during transportation.
4.4.3 Avoid solarization and getting wet in rain and snow during transportation.

4.5 Working condition

• 

Enironment temperature:5

0

C to 40

0

C

•  Relative humidity: ≤80%
• 

Atmosphere pressure: 70kPa to 106kPa

5. After service

We offer one year’s free repair to the equipment according to the warranty card. The repair of the 
equipment should be carried out by our professional technicians. We are not responsible for any 

6. Symbol instruction

Consult the accompanying documents

Type BF applied part

Socket for the foot switch

Atmospheric pressure for storage

Date of manufacture

Used indoor only

24VAC power supply socket

Anti-drip device

Temperature

Class II equipment

Alternating current

Ajustment for the water flow

Humidity Limitation

Manufacturer

Can be autoclaved

Water entrance pressure 0.01MPa to 0.5Mpa

Appliance compliance WEEE directive

Summary of Contents for Comfort-Sonic P6 Plus

Page 1: ...Comfort Sonic Ultrasonic Scaler P6 Plus Instruction for Use...

Page 2: ...3 2 Sterilization of scaling tips and endochuck P10 3 3 Serilization of torque wrench and edo wrench P10 3 4 Cleaning of tips endochuck torque wrench and endo wrench P10 3 5 Sterilization and cleanin...

Page 3: ...for scaling These features make COMFORT SONIC become a new generation product in the world dental market 1 2 Components 1 2 1 The components of the machine are listed in the packing list The scaling...

Page 4: ...gree against water used on the foot switch IPX1 Degree of safety of application in the presence of a Flammable Anesthetic Mixture with air or with Oxygen or Nitrous Oxide Equipment is not suitable for...

Page 5: ...icture 2 picture 2 picture 1 b Socket for foot switch Socket for power supply Water entrance Power switch Water control knob Plug of foot switch Foot switch socket Power supply Power cord plug Power c...

Page 6: ...chable handpiece are showed in picture 4 e Sketch map for how to install tip and endpchuck with wrench are showed in picture 5 LED lamp Nipple Light pipe Handpiece decorative ring The connector of cab...

Page 7: ...ugh to the power See picture 2 Switch on the main unit then the scaling indicator and the leading five lights of power regulator shine Step on the foot switch the tip begins to vibrate and the LED lam...

Page 8: ...the high temperature and pressure The connector of the cable Connect the handpiece with the water source and power supply of the main unit LED lamp Light pipe Clean them with purified water and steril...

Page 9: ...responsible for any damage of the torque wrench directly or indirectly made by any way in the above items 3 Sterilization and maintenance 3 1 Sterilization of detachable handpiece 3 1 1 Autoclaved in...

Page 10: ...Clean the water pipe by multi function syringe note 2 3 6 1 Troubleshooting The following sterilizing methods are forbiden a Putting handpiece into any liquid for boiling b Dipping handpiece in disinf...

Page 11: ...nge to a new O ring The ultrasonic doesn t vibrate The screw is loosen Tighten it Endochuck is damaged Change to a new endochunck LED light doesn t work Poor contact Contact tightly Something wrong wi...

Page 12: ...he socket easy to pull out to make sure it can be pull out in emergency 4 1 14 The device can only be equipped with the special power supply of original manufacturer 4 1 15 The power supply is NOT wat...

Page 13: ...don t invert it 4 4 2 Don t put it together with dangerous goods during transportation 4 4 3 Avoid solarization and getting wet in rain and snow during transportation 4 5 Working condition Enironment...

Page 14: ...h upon examination by Beyes prove to be defective This warranty extends only to the first retail purchaser of a product and is not transferable or assignable Replacement components or products may be...

Page 15: ...zed to sell the product at issue in the geographic territory where the purchaser is located or is not authorized to sell the product at issue within the medical animal health or dental market as the c...

Page 16: ...of the states in which he or she practices to use or order the use of this device 0197 Beyes Dental Canada Inc 23 595 Middlefield Road Toronto Ontario M1V 3S2 Canada Tel 1 855 603 1888 Fax 1 855 720 1...

Reviews: