4
OPERATING INSTRUCTIONS
MAINTENANCE
I.
Remove Lexan water pan cover.
2.
Fill water pan to 3/4 full (hot tap water is recommended when starting your proofing operation).
3.
Replace Lexan water pan cover.
4.
Set thermostat (black knob) to desired proofing temperature (90° to 100°F is recommended as a
starting position - increase or decrease as needed to best suit your product).
5.
Set humidity control (white knob) to position #3. This can then be adjusted if necessary to suit your
specific product.
6.
Make certain that a standard 18" X 26" pan has been inserted as a drip pan in the runners on the
bottom (outside) of the proofer.
7.
Push the lighted power switch to the ON position.Always turn the unit ON or OFF with this control.
It is recommended that humidity to be kept to the minimum level that is practical for your product. Excessive
humidity with condensation on the walls and floor of the cabinet is not considered desirable. You should
attempt to maintain the water pan at a level of ½ full to ¾ full during operation.
This product was designed and built for maximum sanitation. It is not self cleaning, so it should be cleaned
frequently with soap and water.
NEVER USE STEELWOOLOR CAUSTIC CLEANING COMPOUNDS
1.
Make sure that the unit is turned off.
2.
Unplug from electrical service.
NOTE:
CLEANING
3.
Remove Lexan doors by lifting them up and pulling out the bottom edge first.
4.
Remove pan supports from sides and center of cabinet, and then remove the two Lexan
water pan covers.
5.
Clean inside of cabinet with soap and water. Clean clear Lexan water pan covers and
Lexan cabinet doors with soft sponge, soap and water. NEVER USE HARSH
MATERIALS OR ABRASIVES FOR CLEANING LEXAN, thereby avoiding scratching.
6.
Remove the 18" X 26" collector pan from underneath the cabinet and empty and clean as
needed.
Phone the BevLes Company Manufacturing Facility for the name of the nearest authorized service
representative in your area . (800) 441-1601.
If replacement parts are ever required, only use parts that have been approved by the manufacturer.
See Warranty on page 11. To determine if your cabinet is still covered by warranty, telephone the BevLes
Manufacturing Facility at (800) 441-1601. Give them the serial and model numbers which are located on the
product identification plate at the right end of the control module.
We suggest that you clean the water pan at least once a month with a solution of white vinegar and
hot water. Allow solution to remain in the water pan overnight. Use a soft cloth to wipe away any
mineral buildup. Do not use any harsh cleaning solutions on this cast aluminum water pan. Do not
scratch the inner surface of the pan as this will result in more rapid mineral buildup.
SERVICE