Enjoying the light

Sit as close as possible to the lamp, between 10 cm and 40 cm. You can go about your normal activities 

while using it. You can read, write, make telephone calls, etc.

•   Every so often, briefly look directly into the light, since the effect results from the eyes/ retina receiving 

the light.

•   Use the daylight therapy lamp as often as you want. However, the treatment is at its most effective if 

you carry out the light therapy according to the prescribed time period of at least 7 successive days.

•   The most effective time of day for the treatment is between 6am and 8pm  

 and we recommend that it is used for 2 hours per day.

•   Do not look directly into the light the whole time you are using it, however, since that could lead to 

overstimulation of the retina.

•  Start with shorter periods of illumination, which you increase over the course of a week.

Note:

Eye aches and headaches may arise after the first times using the lamp. These will go

away in later sessions, as the nervous system will become accustomed to the new stimulation.

6

Important instructions

When using the lamp, maintain the recommended distance of 10 - 40 cm between your face and the 

lamp. The duration of the application depends on the distance:

Distance

Duration

Up to 10 cm

½ hour/day

Up to 25 cm

1 hour/day

Up to 40 cm

2 hours/day

Basically, the closer you are to the source of light, the less time you should use it.

7

Enjoying light over longer periods

Repeat your use of the lamp in the dark seasons for at least 7 successive days, or even longer, depen-

ding on your individual needs. If possible, conduct the treatment in the morning hours.

8

Switching off the lamp

Press the On/Off button. The LEDs switch off. Unplug the mains part from the mains socket.

CAUTION!

The light remains hot after use.. Let the lamp cool off first long enough before you put it away and/or pack 

it up!

7. Cleaning and care of the unit

The unit should be cleaned occasionally.

Important

•  Ensure that no water penetrates inside the unit! 

Before you clean the unit, always switch it off, unplug it and let it cool off.

•  Do not wash the unit in a washing machine! 

Use a slightly damp cloth to clean the device.

•  Do not touch the unit with wet hands while it is plugged in; do not allow any water to be sprayed onto the 

unit. The unit must be operated only when it is completely dry. 

Do not use abrasive detergents and never immerse the unit in water.

8. Storage

If you are not going to use the device for an extended period of time, disconnect it and store it in a dry place, out 

of the reach of children.

Follow the storage instructions provided in the “Technical data” chapter.

Summary of Contents for TL 70

Page 1: ...EN Daylight therapy lamp Instruction for use 2 ELECTROMAGNETIC COMPATIBILITY INFORMATION 9 TL 70 0598...

Page 2: ...ss This hormone tells the body when it is time to sleep In the months when there is less sunlight therefore production of melatonin increases This makes it harder to get up in the morning since the bo...

Page 3: ...ble to other users and observe the information they contain Safety notes Warning The light of the daylight therapy lamp is only intended for use on the human body Before use ensure that all packaging...

Page 4: ...unit can be dangerous and may cause injury or improper results The main material of the case is made of PC ABS Be cautious of potential allergic reactions to these ma terials General notes Important...

Page 5: ...t 6 Operation 1 Insert the mains part into the connector 2 Switch on the light Press the ON OFF button 3 LED display timer The daylight therapy lamp TL 70 indicates your current treatment time with th...

Page 6: ...n the distance Distance Duration Up to 10 cm hour day Up to 25 cm 1 hour day Up to 40 cm 2 hours day Basically the closer you are to the source of light the less time you should use it 7 Enjoying ligh...

Page 7: ...m Operating conditions 5 C to 35 C 15 90 relative humidity atmospheric pressure range 86 106 kpa Storage conditions 20 C to 50 C 15 90 relative humidity atmospheric pressure range 86 106 kpa Product c...

Page 8: ...first in stance see the attached International Service list of service addresses The buyer will then receive further information about the processing of the warranty claim e g where they can send the...

Page 9: ...t Compliance Electromagnetic environment guidance RF emissions CISPR 11 Group 1 The models TL 70 use RF energy only for its internal function Therefore its RF emissions are very low and are not likely...

Page 10: ...cal commercial or hospital environment Surge IEC 61000 4 5 1 kV line to line 2 kV line to earth 2 kV line to earth Mains power quality should be that of a typical commercial or hospital environment Vo...

Page 11: ...trengths from fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur In the vicinity of equip...

Page 12: ...ing a minimum distance between portable and mobile RF communications equipment transmitters and the model TL 70 as recommended below according to the maximum output power of the communica tions equipm...