background image

11

13. Warranty / Service

Beurer GmbH, Söflinger Straße 218, 89077 Ulm, Germany (hereinafter referred to as “Beurer”) provides a war-

ranty for this product, subject to the requirements below and to the extent described as follows.

The warranty conditions below shall not affect the seller’s statutory warranty obligations which ensue 

from the sales agreement with the buyer. 

The warranty shall apply without prejudice to any mandatory statutory provisions on liability.

Beurer guarantees the perfect functionality and completeness of this product.

The worldwide warranty period is 3 years, commencing from the purchase of the new, unused product from 

the seller.

The warranty only applies to products purchased by the buyer as a consumer and used exclusively for perso-

nal purposes in the context of domestic use.

German law shall apply.

During the warranty period, should this product prove to be incomplete or defective in functionality in accor-

dance with the following provisions, Beurer shall carry out a repair or a replacement delivery free of charge, in 

accordance with these warranty conditions.

If the buyer wishes to make a warranty claim, they should approach their local retailer in the first in-

stance: see the attached “International Service” list of service addresses.

 

The buyer will then receive further information about the processing of the warranty claim, e.g. where they can 

send the product and what documentation is required. 

A warranty claim shall only be considered if the buyer can provide Beurer, or an authorised Beurer partner, with 

- a copy of the invoice/purchase receipt, and 

- the original product. 

The following are explicitly excluded from this warranty: 

-  deterioration due to normal use or consumption of the product;

-  accessories supplied with this product which are worn out or used up through proper use (e.g. batteries, 

rechargeable batteries, cuffs, seals, electrodes, light sources, attachments and nebuliser accessories); 

-  products that are used, cleaned, stored or maintained improperly and/or contrary to the provisions of the 

instructions for use, as well as products that have been opened, repaired or modified by the buyer or by a 

service centre not authorised by Beurer; 

-  damage that arises during transport between manufacturer and customer, or between service centre and 

customer;

-  products purchased as seconds or as used goods;

-  consequential damage arising from a fault in this product (however, in this case, claims may exist arising 

from product liability or other compulsory statutory liability provisions). 

Repairs or an exchange in full do not extend the warranty period under any circumstances.

Summary of Contents for LR 200

Page 1: ...EN Air purifier Instructions for use LR 200...

Page 2: ...posed of Dear customer Thank you for choosing one of our products Our name stands for high quality thoroughly tested products for applications in the areas of heat gentle therapy blood pressure diagno...

Page 3: ...ticles to themselves due to the pull of the electric charge Due to this higher concentration and the formation of larger particles the particles are then collected in the ioniser collector or land on...

Page 4: ...to disconnect the plug from the socket Never hold or carry the device by the mains cable Keep the cables away from hot surfaces Always switch off the device before disconnecting it from the mains Nev...

Page 5: ...vice is intended for private use WARNING If you suffer from severe respiratory or lung disease consult your doctor before using the air cleaner This device must only be used for the purpose for which...

Page 6: ...s three timer periods 2H two hours 4H four hours and 8H eight hours 6 Initial use 6 1 Removing the air purifier 1 Open the cardboard packaging 2 Remove the device from the top of the box without openi...

Page 7: ...mode Note 1 x press ON OFF ION LED illuminates 2 x press ON ON ION LED illuminates Sleep LED flashes 3 x press OFF ON ION LED goes out Sleep LED flashes 4 x press OFF OFF Sleep LED goes out If sleep m...

Page 8: ...the top and then at the bottom 3 Pull out the pre filter Now to pull out the combi filter pull carefully on the side tabs 4 Insert a new combi filter To insert the combi filter correctly align it wit...

Page 9: ...n the HEPA filter Activated carbon filter HEPA filter H 13 Front Rear IMPORTANT The three layered filter should be changed after 4320 operating hours see Filter change section The three layered filter...

Page 10: ...e filters see Mainte nance and storage section The filters are not correctly inserted Insert the filters correctly The air cleaner is positioned on an uneven surface Position the air cleaner on a leve...

Page 11: ...ee the attached International Service list of service addresses The buyer will then receive further information about the processing of the warranty claim e g where they can send the product and what...

Page 12: ...12 686 81_LR200_HEPA_2019 12 27_01_IM1_FITZ Subject to errors and changes BEURER GmbH S flinger Str 218 89077 Ulm Germany www beurer com www beurer healthguide com...