Beurer IH 18 Instructions For Use Manual Download Page 3

3

20

PAP

Dispose of packaging in an environmen-

tally friendly manner

3. Safety information and warnings

 Warning

•  Before use, ensure that there is no visible damage to 

the unit or accessories. When in doubt, do not use 

the unit and contact your dealer or the customer 

service address provided.

• In the event of device faults, please see Chapter "10. 

Troubleshooting".

•  Using the unit is not a substitute for consultation with 

or treatment from a physician. Whenever you have 

any pain or illness, always contact your physician first.

•  If you have health concerns of any kind, contact your 

general practitioner!

• When using the atomiser, always follow the basic 

hygiene procedures.

• Always follow your doctor’s instructions regarding 

the type of medicine to be used and the dose, fre-

quency, and duration of inhalation.

• Only use medicines that have been prescribed or 

recommended by your doctor or pharmacist.

 

Please note: 

  For treatment, only use parts indicated by your doc-

tor according to the particular diagnosis.

• Check whether there are contraindications for use 

with the usual systems for aerosol therapy on the 

medication instruction leaflet.

• If the unit does not function correctly or if you begin 

to feel unwell or feel pain, stop using the unit im-

mediately.

• During use, hold the unit away from the eyes, as some 

nebulised medicines may cause damage to the eyes.

•  Do not operate the unit in the presence of flammable 

gases.

• This device is not intended to be used by children 

or persons with restricted physical, sensory (e.g. 

insensitivity to pain) or mental abilities or persons 

lacking in the required experience or knowledge for 

safe operation of the device, unless supervised or 

instructed by a person responsible for their safety.

• Check in the medicine package leaflet for pos-

sible contraindications for use with common 

aerosol therapy systems.

• The device must be switched off and the plug pulled 

out before every cleaning and/or maintenance pro-

cedure.

• Keep children away from packaging materials (risk 

of suffocation).

• To avoid the risk of entanglement and strangulation, 

store cables and air lines out of the reach of small 

children.

• Do not use attachments that are not recommended 

by the manufacturer.

• Connect the unit only to the mains voltage listed on 

the type plate.

•  Do not dip the unit into water and do not use it in wet 

rooms. Do not allow any liquid to penetrate the unit.

• Protect the unit from strong impacts.

• Never touch the mains cable with wet hands, this 

can cause an electric shock.

• Do not pull the mains plug from the socket by the 

cord.

• Do not pinch or bend the mains cable, pull it over 

sharp objects, or allow it to hang freely, and protect 

it against sources of heat.

• We recommend that the power cable is completely 

unrolled to avoid dangerous overheating.

• If the mains connection cable of this device is dama-

ged, it must be disposed of. If it cannot be removed, 

the device must be disposed of.

•  Opening the unit carries a risk of electric shock. Dis-

connection from the mains supply is only guaranteed 

if the mains plug has been removed from the socket.

• Do not use the unit if it has fallen or been dropped 

on the floor, been exposed to extreme humidity or 

is otherwise damaged. In case of doubt, contact our 

customer service department or your local dealer.

• The IH 18 nebuliser must only be used with suitable 

atomisers and with the appropriate accessories. The 

use of other atomisers and accessories can impair 

therapeutic efficiency and may damage the device.

 Important

• Power cuts, sudden faults or other unfavourable 

conditions may render the unit unusable. You are 

therefore recommended to keep a spare device or 

replacement medicine (as agreed with the doctor).

• If adapters or extensions are required, these must 

comply with the applicable safety regulations. The 

electrical capacity and the maximum capacity speci-

fied on the adapter must not be exceeded.

• The unit and the mains cable must be stored away 

from sources of heat.

• Do not use the unit in a room in which a spray has 

previously been used. If this is the case, ventilate the 

room before commencing treatment.

• Do not allow any objects to enter or obstruct the 

ventilation openings.

•  Do not use the device if you notice an unusual noise.

• For hygiene reasons, each user must use his own 

accessories.

• Always disconnect from the mains after use.

• Store the device in a location protected against en-

vironmental influences. The device must be stored 

in the specified ambient conditions.

Summary of Contents for IH 18

Page 1: ...IH 18 EN Nebuliser Instructions for use ...

Page 2: ...chi deep into the lungs Exhale normally Once prepared the device is suitable for reuse The prep aration includes the replacement of all accessory parts including atomiser and air filter as well as disinfection of the surfaces of the device with a standard disinfectant Please note that all accessories should be replaced if the device is used by more than one person We recommend that you replace the...

Page 3: ...ldren Do not use attachments that are not recommended by the manufacturer Connect the unit only to the mains voltage listed on the type plate Do not dip the unit into water and do not use it in wet rooms Do not allow any liquid to penetrate the unit Protect the unit from strong impacts Never touch the mains cable with wet hands this can cause an electric shock Do not pull the mains plug from the s...

Page 4: ...gainst dust dirt and moisture Never cover the unit during operation Do not use the unit in very dusty environments Switch the unit off immediately if it is defective or malfunctioning The manufacturer shall not be held liable for damage or injuries caused by improper or incorrect use Repairs Note Never open or attempt to repair the unit yourself as otherwise proper function is no longer guaranteed...

Page 5: ...t medicines are to be inhaled in suc cession during therapeutic use the atomiser 7 must be rinsed under warm tap water after each use For information about this see Cleaning and disinfec tion on page 7 Follow the instructions for changing the filter con tained in these instructions Before each use check that the hose connections on the nebuliser 4 and the atomiser 7 are tight Before use check that...

Page 6: ...g and drops for application to the skin or for use in steam baths are wholly unsuitable for inha lation using a nebuliser These substances are often highly viscous and can impair the correct function of the device and hence affect the effectiveness of its application in the long term In the case of oversensitivity of the bronchial system medicines containing essential oils can sometimes cause acut...

Page 7: ...ver use any substances that may be poisonous when in contact with the skin or mucous membranes or when swallowed or inhaled Use a soft dry cloth and non abrasive cleaning prod ucts to clean the device Do not use abrasive detergents and never immerse the unit in water Important Ensure that no water penetrates inside the unit Do not put the device or accessories in a dishwasher Do not touch the unit...

Page 8: ...ocal authorities 10 Troubleshooting Problem Ques tion Possible Cause Remedy The atomiser produces little or no aerosol 1 Too much or too little medicine in the atomiser Minimum 2 ml Maximum 8 ml 2 Check that the nozzles are not blocked If necessary clean the nozzle e g by rinsing Use the atomiser again CAUTION Only poke imple ments through the fine holes from the underside of the nozzle 3 The atom...

Page 9: ...060 hPa Aerosol Properties Flow 5 31 l min Aerosol delivery 0 171 ml Aerosol delivery rate 0 082 ml min Particle size MMAD 3 16 µm The serial number is located on the device or in the battery compartment Subject to technical modifications Particle size diagram Measurements were performed using a sodium fluoride solution with a Next Generation Impactor NGI This diagram may not be applicable for sus...

Page 10: ...er sonal purposes in the context of domestic use German law shall apply During the warranty period should this product prove to be incomplete or defective in functionality in accord ance with the following provisions Beurer shall carry out a repair or a replacement delivery free of charge in accordance with these warranty conditions If the buyer wishes to make a warranty claim they should approach...

Page 11: ...11 ...

Page 12: ...12 601 16_IH18_2019 12 16_05_IM2_BEU_EN Beurer GmbH Söflinger Straße 218 89077 Ulm Germany www beurer com www beurer healthguide com ...

Reviews: