3. Important notes
signs and symbols
The following symbols are used in these instructions for use, on the packaging and on the type plate for the de-
vice and accessories:
Caution
Manufacturer
Note
Note on important information
-20°C
60°C
Temperature limitation
Follow the instructions for use
RH 10-93%
Permissible storage air humidity
Type B applied part
Keep dry
Direct current
sN
Serial number
Disposal in accordance with EC Directive
2002/96/EC – WEEE (Waste Electrical
and Electronic Equipment).
0123
The CE labelling certifies that the product
complies with the essential requirements
of Directive 93/42/EWG on medical pro-
ducts.
Instructions for application
•
Always measure your blood pressure at the same time of day to guarantee comparable values.
•
Before every measurement, relax for about five minutes.
•
Always wait 5 minutes between two measurements!
•
Do not take a measurement within 30 minutes of eating, drinking, smoking or exercising.
•
Please repeat the measurement if you are unsure of the measured value.
•
The measurements taken by you are for your information only – they are no substitute for a medical examination!
Discuss the measurements with your doctor, and never base any medical decisions on them (e.g. medicines
and their administration)!
•
Do not use the blood pressure monitor on newborns, pregnant women and patients with preeclampsia.
•
Erroneous measurements or interference with the measurement accuracy of the unit can arise from diseases
of the cardiovascular circulation system, just as from very low blood pressure, diabetes, blood circulation and
arrhythmias as well as from chills or shaking.
•
The blood pressure monitor must not be used in connection with a high-frequency surgical unit.
•
Only use the unit on people that have the specified upper arm measurement for the unit.
•
Please note that pumping up the cuff can sometimes lead to impairment of the function of the limb concerned.
•
During the blood pressure measurement, the blood circulation must not be stopped for an unnecessarily long
time. If the device malfunctions remove the cuff from the arm.
•
Avoid any mechanical restriction, compression or sharp bending of the cuff line.
•
Do not allow sustained pressure in the cuff or frequent measurements, as the resulting restriction of the blood
flow may cause injury.
Summary of Contents for BM 90
Page 75: ...75...
Page 77: ...77 LCD display signal 24 12 1 7 5...
Page 78: ...78 5 BM90 LAN www beurer connect com LAN 1 5 LR 03...
Page 79: ...79 Pb Cd Hg MEM 3 SET MEM SET 24 12 SET 071 50...
Page 80: ...80 6 22 42 5 START STOP START STOP...
Page 81: ...81 beurer connect 60 START STOP 1 5 7 5 140 90 1 140 159 90 99 2 160 179 100 109 3 180 110...
Page 82: ...82 8 60 MEM MEM 1 60 4 4 MEM SET START STOP 1 MEM 3 SET 9 10...
Page 103: ...103...
Page 104: ...104 752 995_0912 Irrtum und nderungen vorbehalten...