INSTALLATION AND COMMISSIONING
Safety information
HR-Mini
Tank cleaning machine
19
5
Installation and commissioning
5.1
Safety information
WARNING
Risk caused by static charging!
Tanks may be subject to static charging during the cleaning process.
If your hand touches the tank, it may cause you to suffer an electric
shock or an irritating effect than can result in a nervous reaction.
This may result in death or serious injury.
•
Work on the HR-Mini should only be carried out by fully trained
specialists.
•
Make sure electrostatic charging is prevented. To do so, ground
the HR-Mini and the tank to the same potential.
•
Always carry out grounding before commissioning the HR-Mini.
5.2
Installation position
The HR-Mini is intended for vertical installation with the cleaning head facing
downwards. If other installation positions are chosen, moisture can enter the
drive and damage the HR-Mini.
5.3
Installation
Always read the safety information in section “5.1 Safety information” before in-
stalling the HR-Mini in the tank.
The HR-Mini is installed in the tank opening using the supplied 2" collar.