12
18. SOLUTION TANK
Remove the front inlet cap and check the solution filter is correctly installed.
Check the filter cap (beneath the solution tank, at the back) is correctly closed.
19. SOLUTION TANK
Fill the tank with clean water in the front fill location (
1
) at a temperature not ex-
ceeding 120°F (50°C). You can check the level of solution in the tank by means
of the rear hose (
2
).
Add liquid detergent into the tank, in the concentration and manner specified
by the manufacturer. The formation of excess foam could damage the vacuum
motor, so be sure to use only the correct amount of detergent.
WARNING: Always use low-foam detergent. Introduce a small
amount of defoaming liquid in the recovery tank before starting
work to prevent foam from being generated.
WARNING: Never use pure acids.
20. ASSEMBLING THE BRUSH
A. With the brush deck up, place the brush and center it under the brush deck.
B. Lower the brush deck, turn the key (
1
) to position “1”, pull the switch levers
(
2
) on the handlebars.
The brush in now installed.
WARNING: Make sure there are no objects or people in the vicin-
ity of the brush when doing this operation.
MACHINE PREPARATION
Summary of Contents for Stealth ASD20BT
Page 22: ...22 BRUSH DECK DIAGRAM BEFORE SERIAL NUMBER 214999999 ...
Page 34: ...34 SQUEEGEE YOKE DIAGRAM BEFORE SERIAL NUMBER 214999999 ...
Page 38: ...38 MAIN FRAME DIAGRAM BEFORE SERIAL NUMBER 214999999 ...
Page 50: ...50 SOLUTION DELIVERY DIAGRAM 2 4 2 8 7 1 5 2 2 3 ...
Page 56: ...56 ELECTRICAL DIAGRAM BEFORE SERIAL NUMBER 214999999 ...
Page 58: ...58 ELECTRICAL DIAGRAM AFTER SERIAL NUMBER 215000000 ...
Page 66: ...66 ...
Page 67: ...67 ...