8
6. TURN ON HEAT SWITCH
If hot water is desired for cleaning, turn on the heater switch and wait two minutes for the heater to reach operating
temperature.
7. PRE-SPRAY AREA
Pre-spray the area to be cleaned with the appropriate Betco
®
cleaning detergent. If you choose to add a detergent to the solution
tank, be sure to mix well and always follow the use and dilution instructions on the chemical label. Use a Betco cleaning deter-
gent with a pH between 5 and 10 to reduce the likelihood of premature wear to the pump and other seals. If excess foaming
occurs, use Betco defoamer to prevent damage to electrical components. Water damage to the vacuum motor is not covered by
the warranty.
8. BEGIN CLEANING
Once all of the switches are turned on, squeeze the trigger on the tool and pull the hand tool in a backward motion. Release the
trigger a few inches before finishing the stroke to ensure he vacuum shoe will pass over the wet area. Then push the tool in a
foward motion back over the same clean path to remove and residual water. Continue in this manner until the entire area has
been cleaned.
9. MONITOR WATER LEVELS
Montior the water level in the solution tank. Do not let the pump run dry. When the solution level gets low, turn off the pump
and vacuum, refill the solution tank, and empty the dirty water from the recovery tank. The machine has a suction shut-off float
in the recovery tank to prevent overflow. If the suction stops, turn off the machine, remove and empty the recovery tank.
10. FINISHING THE JOB
When finished with the job, remove any unused solution from the clean water tank and run a few gallons of clear water through
the system. Drain the recovery tank into a drain or bucket through the vacuum hose connection on the front of the machine.
Disconnect the hoses from the machine and the cleaning tool.