7
7.
FASTDRAW
®
System Installation
(continued)
Step 1: Mounting the Proportioner to the Wall
(continued)
4. Connect the supplied 6’ braided water supply hose to
the right side of the dispenser and the water line. Tighten
both connections by hand. Mount the water supply line
to the wall with proper clamps to avoid damaging the dis-
penser. Slowly turn on the water supply to check for any
leaks. You may need to tighten an additional 1/4 turn with
pliers, but be careful not to over tighten.
5. *Push and twist the plastic short hose over the barbs in
the 1 GPM green eductor on the right side. Push and
twist the plastic long hose over the barbs in the 4 GPM
white eductor on the left side. Make sure the hoses are
secured tightly.
*NOTE:
For 91069-00 air gap dispensers, you must first
insert the small, thin priming tube onto the 1 GPM green
eductor on the right side. Then place the clear plastic
short hose over the small priming tube and onto the
barbs.
6. Make sure that the hook portion of the hanger is near the
open end of the hose. (See diagram to the left.) Hook the
bucket-fill hose onto the slot on the left side of dispenser.
7. Hang the clear folder with the product literature sheets/
MSDS next to the dispenser. Hang the Operation Chart
on other side of the dispenser for training and reference.
Summary of Contents for Fastdraw