This will automatically start the battery charging process.
After setting the battery voltage to the 24V mode, set the charging parameters using the “Function” key:
4A
Charge for 24V batteries, 5Ah to 80Ah
Maintenance charge for 24V batteries, 5Ah to 120Ah
Suitable for charging
WET and Gel batteries
8A
Charge for 24V batteries, 50Ah to 160Ah
Maintenance charge for 24V batteries, 50Ah to 250Ah
Suitable for charging
WET and Gel batteries
4A
Charge for 24V batteries, 5Ah to 80Ah
Maintenance charge for 24V batteries, 5Ah to 120Ah
Suitable for charging
AGM-START&STOP and AGM-SPIRAL and EFB batteries
8A
Charge for 24V batteries, 50Ah to 160Ah
Maintenance charge for 24V batteries, 50Ah to 250Ah
Suitable for charging
AGM-START&STOP and AGM-SPIRAL and EFB batteries
The battery is charging.
The green LED flashes.
The battery is fully charged (100%); the battery charger will switch to the maintenance step, ke-
eping the state of efficiency of the battery constantly monitored, so that it is always at an optimal
level of charge. The green LED is steadily on.
This will automatically start the battery charging process.
Charge indicators:
INTERRUPTION OF CHARGE CYCLE IN CASE OF MAINS BLACKOUT
In case of blackouts in the 230V mains, the battery charger saves the work cycle it was performing, in order to restore it automati-
cally as soon as the power supply of the 230V mains is restored. This function is crucially important if the battery charger is used
to charge batteries without the operator supervising the cycle; for example, during very long work cycles (maintenance charges)
or when charging overnight (charges for vehicles that need to be charged daily).
END OF CHARGING
1. Unplug the power supply lead of the battery charger from the mains.
2. Disconnect the output lead with black clamp from the vehicle's earthing point or the negative terminal (-) of the battery.
3. Disconnect the output lead with red terminal from the positive terminal (+) of the battery.