GFCI WARNING

WARNING:

 Risk of electric shock. The GFCI must be tested before 

each use.

WARNING:

 Do not use the pump if this test fails. For assistance, 

please visit the support section on our website, www.bestwaycorp.com.

POOL SUCTION FITTING 

INSTRUCTIONS

When installing and using this equipment, basic safety precautions shall always be 

followed, including the following:

IMPORTANT SAFETY INSTRUCTIONS

READ, FOLLOW, AND UNDERSTAND 

ALL INSTRUCTIONS AND WARNINGS.

- Any modification that increases the flow rate of the circulation system shall require 

re-evaluation of the cover/grate and sump to ensure that the flow rating of the 

Suction Outlet Fitting Assembly (SOFA) is not exceeded.

- Missing, broken, or cracked cover/grates, sumps, mud-frames, or any other SOFA 

component shall be replaced before bathers are allowed to use the pool.

- Loose cover/grates shall be reattached before bathers are allowed to use the pool.

1. Replace suction fittings every 2 years.

2. The use of adhesives or other attachment methods that prevent access to suction 

piping or SOFA components requiring periodic servicing is prohibited. 

3. Refer to the following diagram for each SOFA 

component part instructions:

4. - Any field modification made to a SOFA not 

authorized by the manufacturer’s installation 

instructions shall void the SOFA certification.

 - No modification shall be made to a SOFA 

structure or flow path unless the new 

configuration has been certified as new SOFA.

 - Cover/grates and all other SOFA components 

shall be replaced at or before the end of their 

service life and that service life begins the 

month and year in which a SOFA component is 

installed with or without water.

5. Winterizing instructions. Dry the suction fittings completely, and store the product 

in a dry room at a storage temperature of 15 

℃ 

~ 40 

.

6. Use the screwdriver (not included) to disassemble the suction fitting to clean or 

service.

- Cover/grate, including fasteners, shall be observed for damage or tampering 

each operational day.

- Missing, broken, or cracked cover/grates shall be replaced before bathers are 

allowed to use the pool.

- Loose cover/grates and associated components shall be reattached before 

bathers are allowed to use the pool.

- SOFA components and fastener receptacles shall be clean and free of debris or 

obstructions during installation of cover/grate and fasteners.

- Remember to hand-check cover/grate for snugness to the sump/ frame after 

installation.

7. Before using the product, please check the integrity of the head of the suction 

fitting. If the product is broken, please do not use it.

8. - All SOFAs shall be installed in accordance with the manufacturer’s installation 

instructions.

- No modification shall be made to a SOFA structure or flow path unless the new 

configuration has been certified to the original SOFA.

- These SOFA-configuration specific flow ratings NOT be exceeded at any time 

the pool is open to bathers.

- Cover/grates, when installed, shall not protrude more than 2 in. (51 mm) from 

the finished surface of the pool in which the SOFA is installed

9. 

Please research and download General Certificate of Conformity through 

www.bestwaycorp.com

SAVE THESE INSTRUCTIONS

Summary of Contents for Hmax 58498E

Page 1: ...UCT TO THE STORE QUESTIONS PROBLEMS MISSING PARTS For FAQ Manuals Videos Or Spare Parts Please Visit bestwaycorp com support V i s i t w w w bestwaycorp com supp o r t f o r h e l p OWNER S MANUAL bes...

Page 2: ...reset button Power should be restored If the GFCI fails to operate in this manner the GFCI is defective If the GFCI interrupts power to the pump without the test button being pushed a ground current...

Page 3: ...OF ELECTRIC SHOCK CONNECT ONLY TO A GROUNDING TYPE RECEPTACLE CAUTION THIS PUMP IS FOR USE WITH STORABLE POOLS ONLY DO NOT USE WITH PERMANENTLY INSTALLED POOLS CAUTION CONNECT ONLY TO GROUNDING TYPE...

Page 4: ...is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the...

Page 5: ...FA certification No modification shall be made to a SOFA structure or flow path unless the new configuration has been certified as new SOFA Cover grates and all other SOFA components shall be replaced...

Page 6: ...Please research and download General Certificate of Conformity through www bestwaycorp com SAVE THESE INSTRUCTIONS Filter Diameter Effective Fiter Area Max Operating Pressure Working sand filter press...

Page 7: ...S16 P6783ASS16 A 1 1 2 1 1 1 1 1 1 1 1 6 1 1 8 1 2 5 1 1 1 1 1 2 2 1 2 1 2 1 B 1 1 2 1 1 1 1 1 1 1 1 6 1 1 8 1 0 4 1 1 1 1 1 2 2 0 2 1 2 1 C 1 1 2 1 1 1 1 1 1 1 1 5 1 1 8 1 0 0 1 1 1 1 1 2 0 0 0 0 0 1...

Page 8: ...and filter It is specially graded to trap particles in the 20 100 micron range Some small debris can pass throw the sand and back into the pool This is normal especially if the debris is fine or silt...

Page 9: ...MAX MIN 20 0 45 0 85 mm C C C 4 MAX MIN 9 CONNECT TO THE POOL A A B B B A B A B 1...

Page 10: ...10 D A B B 2 3 1 D Garden hose not included For Drain Backwash Rinse function A B B A B B B 2 3 4 P6680ASS16...

Page 11: ...n damage the Control Valve which may cause personal injury or property damage How to Use the Control Valve Press down on the Control Valve handle and rotate to desired function CONTROL VALVE FUNCTIONS...

Page 12: ...through the sand bed and deposited out of Port D C B D A Rinse This function for initial startup cleaning and sand bed leveling after Backwash water is pumped downwards through the sand bed up through...

Page 13: ...is operation every time you start the pump after winterizing maintenance and backwashing the sand bed FIRST TIME USE INSTRUCTIONS Backwash and Rinsing must be performed to prepare the pump for its fir...

Page 14: ...off and unplugged before any maintenance begins or severe risk of injury or death exists As dirt builds up in the sand filter the pressure reading on Pressure Gauge will increase When the Pressure Gau...

Page 15: ...e Drain function 2 Detach the Hose from the connection valve s Port A and sand filter Port A and attach to Port D 3 Switch on the sand filter to remove pool water WARNING DO NOT DRY RUN THE SAND FILTE...

Page 16: ...s under license from Marques utilis es dans certains pays sous la licence de Marcas comerciales utilizadas en algunos pa ses bajo la licencia de Die Warenzeichen werden in einigen L ndern verwendet un...

Reviews: