background image

the scale the lower the temperature. 

""'"" 

2. Press 

"REBOIL" 

to heat water. At this moment

the  light  will  change  from 

"KEEP  WARM" 

to

,,HEATING".

3. In  order  to  cool  water  first  press  the  cold  water

button lever and then 

"COLD POWER" 

button.

CAUTION: 

lf  it  is  not  necessary,  do  not  press 

"COLD POWER" 

button. You can do it again after 3 

minutes 3 min. (in order to protect the compressor). 

Cold  water temperature  is  sei  within  the  range  4-12 

degrees C. 

You can regulate lhe temperature by the use 

..... 

-

-

-

� 

of a  controller  mounted  at the  back  side of 

Waier  Distributor.  The  higher  the  value  on 

10. WATER DISTRIBUTO

SERVICE AND 

MAINTENANCE 

ml)

WATER DISTRIBUTOR CLEANING

1. Make  sure  Waier  Distributor  is  unplugged

before you start cleaning.

2. Remove  the  top  cover,  cool  water  tank

cover and hot water tank cover.

3. By  the  use  of  cold,  cool  and  hol  water

button levers release the remaining water.

4. In order to  empty the cold water tank remove the drain plug from the water tank,

which is is located at the back side of the Waier Distributor.

5. Clean the hol and cool water tanks ONL Y by the use of disinfecting substances

admitted for food industry by appropriate authorities.

CAUTION:  DO NOT  TILT THE WATER DISTRIBUTOR TO THE SIDES DURING CLFANING.  IT 

MA Y  CAUSF  SFVFRF  SYSTEM  DAMAGFS  HY  FLOODING  IT  WITII 

WATFR.  AFTFR  YOU  HAVF  CLFANFD  OR  INSTALLFD  THF  SYSTEM, 

WAIT  10 MINUTFS HEH)RF  YOU PRFSS "COLD WAIER" HUTff)N. 

� 

ß1E 

PREFIL TERS EXCHANGE --

CAUTION:  THE PRODUCER DOES NOT  TAKE REPONSIBILITY  FOR INSTALLING CARTRIDGES, 

MEMBRANES  AND  OTHER  RERVERSE  OSMOSIS  EQUIPMENT  ELEMENTS  DIFFERENT 

THAN  THOSE  PROVIDED  IN  THE  SET.  THE  PRODUCER  IS NOT  LIABLE  FOR  ANY  DAMAGES 

CAUSED  TO  THE  SYSTEMS  DUE  TO  IMPROPER  INSTALLATION  OR  USAGE  OF  WATER 

TREATMENT ELEMENTS. 

15 

Summary of Contents for Jungbrunnen 25-00

Page 1: ...WATER DISTRIBUTOR Jungbrunnen 25 00 With reverse osmosis system INSTRUCTION MANUAL...

Page 2: ......

Page 3: ...n QC type connections 11 7 2 Disconnection of quick connection application QC type 11 connections 8 WATER DISTRIBUTOR INSTALLATION TO WATER MAINS 11 8 1 Installation to cold water inlet 11 8 1 1 METHO...

Page 4: ...05...

Page 5: ...compressor 13 Waste water connection 14 Water connection 15 Power supply 1 Water level indicator Water level indicator 2 Control panel Control panel 3 Hot water tap Hot water tap 4 Cool water tap 5 C...

Page 6: ...4 1 7 5 2 8 6 1 Top cover 2 Outer plate of warm water tank 4 Steam outlet opening 5 Steam outlet cover 6 Hot water tank 7 Cool water tank 8 Hydraulic floating valve...

Page 7: ...ter enters cool water tank A then goes to hot water tank B and cold water tank C Check valve is installed between the cool water tank and hot water tank which prevents hot water from going back to the...

Page 8: ......

Page 9: ...9...

Page 10: ...ply socket Voltage 230 V 50Hz PZ Power supply cable with plug WATER DISTRIBUTOR CW 929 PS Control panel a LED POWER diode b LED KEEPWARM diode c LED HEATING diode d LED diode SP Compressor G Hot water...

Page 11: ...kage before you leave 7 2 Disconnacting tha QC push in fittings 0 Make sure that there is no pressure in the system Push the locking clip to the front of the fitting Take out the tube holding the lock...

Page 12: ...o release the remaining water 3 Unscrew the nut on the installation tube or shut off valve Put on rubber gasket and mount the water feeder element Tighten firmly Screw in the ball valve into the water...

Page 13: ...ly 6 Connect 1 4 tubing to the drain saddle and the other free end to the flow restrictor valve E PRESSURE CONTROL AND SYSTEM RINSING 1 Check all tubes so that there is a free passage 2 Connect Water...

Page 14: ...t the water distributor is connectoed to the pcrNer source ofa properpOYfer voftage and frequency HOW TO GET WATER OF A REQUIRED TEMPERATURE 1 After you connect Water Distributor to power supply press...

Page 15: ...hot water tank cover 3 By the use of cold cool and hol water button levers release the remaining water 4 In order to empty the cold water tank remove the drain plug from the water tank which is is lo...

Page 16: ...idual service programme adjusted to particular raw water conditions ml MEMBRANE EXCHANGE Insert new membrane into housing in this direction Feed _____ 4 1 f L _ Brine Brine Seal Product Membrane Schem...

Page 17: ...SUPPLY The system switches off automatically when water level is lower than the required minimum The system does not start after a short period of power cut off althouqh it was not unpluaaed WATER DO...