BESTEK NSP-10H6 User Manual Download Page 29

 

 

29

 

 

PC

 

Health

 

Status

 

These

 

items

 

display

 

the

 

current

 

status

 

of

 

all

 

of

 

the

 

monitored

 

hardware

 

devices/components

 

such

 

as

 

CPU

 

voltage,

 

temperatures

 

and

 

all

 

fans’

 

speeds.

 

 

 

Chassis

 

Intrusion

 

This

 

setting

 

enables/disables

 

the

 

feature

 

of

 

recording

 

the

 

chassis

 

intrusion

 

status

 

and

 

issuing

 

a

 

warning

 

message

 

if

 

the

 

chassis

 

is

 

once

 

opened.

 

To

 

clear

 

the

 

warning

 

message,

 

set

 

the

 

field

 

to

 

[Reset].

 

The

 

setting

 

of

 

the

 

field

 

will

 

automatically

 

return

 

to

 

[Enable]

 

later.

 

 
 

Serial

 

Port

 

Console

 

Redirection

 

 

Console

 

Redirection

 

Enables

 

or

 

disables

 

Console

 

Redirection

 

function

 

of

 

each

 

Serial

 

Port.

 

 

Console

 

Redirection

 

Settings

 

 

Terminal

 

Type

 

To

 

operate

 

the

 

system’s

 

console

 

redirection,

 

you

 

need

 

a

 

terminal

 

supporting

 

ANSI

 

terminal

 

protocol

 

and

 

a

 

RS

232

 

null

 

modem

 

cable

 

connected

 

between

 

the

 

host

 

system

 

and

 

terminal(s).

 

This

 

setting

 

specifies

 

the

 

type

 

of

 

terminal

 

device

 

for

 

console

 

redirection.

 

Bits

 

per

 

second,

 

Data

 

Bits,

 

Parity,

 

Stop

 

Bits

 

This

 

setting

 

specifies

 

the

 

transfer

 

rate

 

(bits

 

per

 

second,

 

data

 

bits,

 

parity,

 

stop

 

bits)

 

of

 

Console

 

Redirection.

 

Flow

 

Control

 

Flow

 

control

 

is

 

the

 

process

 

of

 

managing

 

the

 

rate

 

of

 

data

 

transmission

 

between

 

two

 

nodes.

 

It’s

 

the

 

process

 

of

 

adjusting

 

the

 

flow

 

of

 

data

 

from

 

one

 

device

 

to

 

another

 

to

 

ensure

 

that

 

the

 

receiving

 

device

 

can

 

handle

 

all

 

of

 

the

 

incoming

 

data.

 

This

 

is

 

particularly

 

important

 

where

 

the

 

sending

 

device

 

is

 

capable

 

of

 

sending

 

data

 

much

 

faster

 

than

 

the

 

receiving

 

device

 

can

 

receive

 

it.

 

Recorder

 

Mode,

 

Resolution

 

100x31

 

These

 

settings

 

enable/disable

 

the

 

recorder

 

mode

 

and

 

the

 

resolution

 

100x31.

 

Legacy

 

OS

 

Redirection

 

Resolution

 

This

 

setting

 

specifies

 

the

 

redirection

 

resolution

 

of

 

legacy

 

OS.

 

 

 

 

Summary of Contents for NSP-10H6

Page 1: ...1 Network Security System NSP 10H6 Always at the forefront of innovation User Manual...

Page 2: ...t 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential installation This equipment generates uses...

Page 3: ...electrical discharge can damage computer components without causing any signs of physical damage You must take extra care in handling them to ensure against electrostatic build up 1 To prevent electr...

Page 4: ...pe recommend by the manufacturer Dispose of used batteries according to local ordinance Before using the system prepare basic system components If the system comes as a barebone that is none of the ke...

Page 5: ...fore You Begin 14 2 2 Precautions 14 2 3 Open Up Top Cover 15 2 4 Accessing Processor Memory 16 2 5 Adding 2 5 3 5 SATA Hard Drive 16 2 6 Accessing CompactFlash Card 18 Chapter 3 Operation 3 1 Turning...

Page 6: ...6 Chapter 1 General Information...

Page 7: ...bypass functions that are configurable through BIOS setting or software programming and are under visual monitoring via the LED indications at front panel Yes further access to full status is also ava...

Page 8: ...s LED LAN 6x RJ45 Ports Console 1x RJ45 Type Console Port USB 2x USB 2 0 Ports Rear I O Switch 1x Rock Type Power Switch VGA 1x Optional DB15 VGA Port Expansion PCIe 1x Straddle Type PCIe X8 Slot Powe...

Page 9: ...Module Chipset Intel 82580EB Interface PCIe X4 Network Port Four RJ45 Gigabit Bypass 1 Pair BEM C600 580 F4 Type LAN Module Chipset Intel 82580EB Interface PCIe X4 Network Port Four SFP Fiber Gigabit...

Page 10: ...10 Figure 1 1 System Layout of NSP 10H6 1 4 System Layout...

Page 11: ...11 Front View With 4 Port RJ45 LAN Module With 4 Port SFP LAN Module 1 5 Indicators Features...

Page 12: ...12 Rear View...

Page 13: ...13 Chapter 2 Preparation...

Page 14: ...environment tend to have less static electricity than dry environments A grounding strap is warranted whenever danger of static electricity exists Computer components and electronic circuit boards ca...

Page 15: ...places below prior to any moving of the top cover It is recommended to push the top cover backwards so as to detach the cover tongue out of the snatch up at front side before the lift up or removal of...

Page 16: ...e Hard Drive bracket red circles as below Remove these screws to acquire the Hard Drive bracket 3 This Hard Drive bracket is designed to hold one 3 5 SATA Drive with also two smaller L bracket for two...

Page 17: ...the brackets are symmentrically designed and add the eight screws enclosed in the accessory screw bag for a perfect and firm Hard Drive subset In case only one 2 5 Hard Drive is to be installed add th...

Page 18: ...e inserting removing or swapping a CompactFlash 4 Restore Hard Drive bracket if needed Please be advised that CompactFlash card on IDE interface is never to be added or removed when the system power i...

Page 19: ...19 Chapter 3 Operation...

Page 20: ...n AC Power Loss Have you wish to bring it down simply press once on the power switch located next to power supply with yellow circle or press and hold for 4 seconds to reach that goal However in most...

Page 21: ...3 Press del to go to BIOS setup menu 4 Choose to confirm SATA Controller status If it is enabled select a SATA mode and go to 6 5 If SATA Controller is disabled bring it up and reboot to allow a re d...

Page 22: ...e Yellow On LAN linked Yellow Blinking LAN accessing Off Off No LAN linked RJ45 NIC Mode Right Side Amber On Gigabit mode Green On 100M mode Off Off 10M mode ByPass LAN LED Both Bypass LED would be co...

Page 23: ...23 Chapter 4 BIOS Setup...

Page 24: ...programshouldbeexecuted underthefollowing conditions Whenchanging thesystem configurations Whena configuration erroris detectedbythe systemand youare promptedto make changes to the Setup program Whenr...

Page 25: ...followingmessageduringthe POST TO ENTER SETUP BEFORE BOOT PRESS CTRL ALT ESC OR DEL KEY Pressthe Del keyor pressthe Ctrl Alt and Esc keysto enterSetup The online description of the highlighted setup...

Page 26: ...system configuration Advanced Advanced system settings Chipset Other functions Boot System boot configuration Security Configure Supervisor and User Password Save Exit Exit options as well as loading...

Page 27: ...CPU Configuration SATA Configuration Super IO Configuration H W Monitor Chassis Function and Serial Port Console Redirection S5 RTC Wake Settings Resume On RTC Alarm When Enabled you can set the date...

Page 28: ...and to be issued during the next boot CPU Configuration CPU Configuration This menu shows the CPU information Read only Limit CPUID Maximum It is designed to limit the listed speed of the processor to...

Page 29: ...protocol and a RS 232 null modem cable connected between the host system and terminal s This setting specifies the type of terminal device for console redirection Bits per second Data Bits Parity Stop...

Page 30: ...ate Restores the system to the previous status before power failure or interrupt occurred Watchdog Time Out Event This setting controls the Watchdog Time Out event LAN1 2 LAN3 6 ByPass state Power On...

Page 31: ...board or system manufacturer s full screen logo When it is enabled the BIOS will display the full screen logo during the boot up sequence hiding normal POST messages When it is disabled the BIOS will...

Page 32: ...you may use the arrow keys to select the desired device then press or PageUp PageDown key to move it up down in the priority list CSM Parameters This setting specifies the parameters for Compatibilit...

Page 33: ...ministrator password only when they enter BIOS Setup User Password User Password controls access to the system at boot and access to the BIOS Setup utility Users will be prompted for User password whe...

Page 34: ...Discard Changes and Exit Abandon all changes and exit Save Changes and Reset Save changes to CMOS and reset the system Discard Changes and Reset Abandon all changes and reset the system Restore Defau...

Page 35: ...35 Chapter 5 Programming Guide...

Page 36: ...PAIR3 1 Ex PAIR3 1 000 Select LAN 1 2 Channel Control PAIR3 1 001 Select 1 Press Alt C Select IO Space Select 0 key in 500 press Enter 2 Select Offset 39 Bit2 set to 1 WDT Bypass 3 Clean Pair1 3 Sele...

Page 37: ...37 Chapter 6 Q A...

Page 38: ...d Remove PCI card and or PCI riser card and boot again 6 Bad external devices Detach RS 232 cable LAN cable and USB cable and boot again Q BIOS POST prompts but gets stuck A Please check the following...

Page 39: ...rmware designed for booting Q Windows XP installer does not find any Hard Drive A Please check the following before you call out for help 1 Check in the BIOS that SATA Hard Drive or CompactFlash has b...

Page 40: ...een RJ45 port and network chip Q Can I enable Bypass function at Power Off mode A Yes you certainly can NSP 10H6 comes with dual latch relay that will work at both power on and power off mode Please b...

Page 41: ...devices if necessary 2 If any of the LAN port is not detected 4 of them should be all detected please go to BIOS setup menu Advanced PCIE Ports Configuration to see if any of them has been disabled Q...

Reviews: