- 5 -
2. PREPARE THE INSTALLATION
When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves.
Make sure that the following items are included:
- Hood
- Accessories
• Decorative flue assembly (lower and upper flues)
• Hood mounting bracket
• Upper flue mounting bracket
• Shielded halogen lamps (120 V, 50 W, MR16 or PAR16 with GU10 base) (2 for
3
0” and
3
6” width hoods,
3
for 42” and 48” width hoods)
• Aluminum grease filters (2 for
3
0”,
3
6” and 42” width hoods,
3
for 48” width hoods)
• 8” round adapter/damper (with
3
0”,
3
6” and 42” width hoods), in a separate box
• 10” round adapter (with 48” width hood)
• Foam strip (with 48” width hood)
• 10” round vertical in-line damper (with 48” width hood)
• Installation manual
• Bag of parts including: 5 no. 8 x 1½” countersunk screws, 8 no. 8 x
3
/4” screws,
6 no. 8 x
3
/8” screws, 6 drywall anchors,
3
washers. If need be, discard extra screws.
Parts sold separately:
- Ducts, elbows, wall and roof caps. Refer to page
3
for a complete list of venting options and model numbers.
- Non-duct kit model ANKWT
3
2, mandatory for non-ducted installation.
- Optional flue extension for 10-ft. celings model nos. AEWT
3
2SB or AEWT
3
248SB.
- Optional make-up air damper model nos. MD6TR or MD8TR.
NOTE: During installation, protect countertop and/or cooktop.
WARNING
!
3. REMOVE GREASE FILTERS
Lay the hood on it’s back on a table. Use a piece of cardboard to avoid damaging
the table or the hood.
Remove grease filters by lifting the metal latch tab (
1
), pushing down on the
filter (
2
) and tilting it towards you (
3
).
HD0376
1
2
3
4. WIRING INSTALLATION
GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by
providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding
plug. The plug must be plugged into an outlet that is properly installed and grounded.
WARNING
Improper grounding can result in a risk of electric shock. Consult a qualified electrician if the grounding
instructions are not completely understood, or if doubt exists as to whether the appliance is properly
grounded. Do not use an extension cord. If the power supply cord is too short, have a qualified electrician
install an outlet near the appliance, in accordance with all applicable codes and standards. Turn off
electrical power at service entrance before wiring.
!