- 11 -
A.
D
ELAY
S
WITCH
:
When a blower speed is selected, press this switch to activate the delay function. The corresponding blower speed switch
will flash to indicate this function is activated. The blower will continue to operate for 5 minutes and will stop automatically.
To cancel the delay function, press the delay switch once again.
B.
S
TART
/S
TOP
/S
PEED
S
ELECTION
S
WITCHES
:
Press the switch corresponding to the desired blower speed (from
1
for low speed to
4
for high speed). The chosen switch
will light. To turn off the blower, press once more on the corresponding blower speed switch; the switch light will shut off.
NOTE: When blower is off, pressing on blower speed
1
switch will cause the blower to start on high speed for a very
short lapse of time, and then resume on speed
1
.
C.
M
ASTER
OFF/F
ILTER
M
AINTENANCE
/H
EAT
S
ENTRY
™ (T
RIPLE
F
UNCTION
S
WITCH
):
i.
To turn off the blower and the light simultaneously, press this switch once.
ii. After 25 hours of operation, this switch will light to indicate the filters and the blower wheel(s) need to be cleaned in
order to maintain efficient operation of the unit. The switch light will stay on until the function is reset by pressing this
switch for
3
seconds.
iii. The light indicator is used for the Heat Sentry function as well.
H
EAT
S
ENTRY
:
When an excessively high temperature is detected, the detector takes control over the blower and
set it on speed
3
; its switch light comes on and the Heat Sentry switch flashes.
The blower will remain on until the heat is back to normal, it then returns to the speed previously selected.
NOTE: In a case of range top grease fire (temperature exceeding 90°C), the Heat Sentry will be deactivated to prevent fire
propagation.
D.
L
IGHT
S
WITCH
:
This switch allows three different lighting levels according to your needs. Press once for nightlight, twice for normal or three
times to obtain full intensity. To shut off the lights without turning off the blower, press once more.
HC0023
WARNING
The Heat Sentry can start the blower even if the hood is turned off. When this situation occurs, it is impossible
to turn the blower off using the push buttons. If you must stop the blower, do it from the main electrical panel.
!
16. OPERATION
Always turn your hood on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few minutes
to clear the air after you turn off the range. This will help keep the whole kitchen cleaner and brighter.
A
B
C
D
17. WIRING DIAGRAM
1 2
J5
J4
BLU
WHT
BLK
ORG
BLK
La
m
p
YEL
WHT
WHT
WHT
BLK
RED
M
BLK
ORG
WHT
BLU
RED
BRN
GRY
WHT
WHT
BLK
J1
J8
J6
T1
FAN SPEED AND
LIGHT CONTROL
YEL
5
4
3
2
1
3
2
1
J2
BLK
J9
1
2
3
1
2
3
4
5
WHT
WHT
J10
BLU
BLU
J15
J11
J12
To Make-up Air
120 VAC
GRN
HE0111A
La
m
p
M
BLK
ORG
WHT
BLU
RED
BRN
GRY
J7
1
2
3
4
5
WHT
J3
La
m
p
YEL
RED
ORG
BLK
WHT
BLU
BLK BLACK
BLU BLUE
BRN BROWN
GRN GREEN
GRY GREY
ORG ORANGE
RED RED
WHT WHITE
YEL YELLOW
COLOR CODE
YEL