Installing the lock
BEST ACCESS SYSTEMS
a Product Group of dormakaba USA Inc.
13
Route wire harness and position
outside escutcheon
1 From the outside of the door, feed the motor
connector, battery connector, door status switch, and
antenna wire, through the harness hole.
Caution:
When routing the connectors, make sure
the wire harness is not routed across any sharp
edges or over any surface that could damage its
sleeving or wire insulation.
2 On the inside of the door, insert the two countersunk
mounting screws into the holes at the top and bottom
of the fire plate.
3 Tighten the mounting screws until the fire plate is
securely mounted to the door.
14
Route wires on fire plate
1 Route the motor connector wire, RQE connector, and
door status connector underneath the side tabs as
shown in Figure 14.
2 Route
the
battery
connector and antenna wire above
the side tabs. See Figure 15 for additional detail.
Figure 13 Feeding the wire harness connectors through
the harness hole
Motor connector
Outside escutcheon
Outside of door
Battery connector
Door status
connector
Antenna wire
RQE connector
Harness hole
RQE connector
Figure 14 Routing the wires on the fire plate
Inside of door
Motor connector
Battery connector
Side tabs
Door
status
connector
Antenna wire
RQE connector
Door status
connector