Wiring diagram

The diagram below shows how to wire 8KW and 9KW electrified locks. 

 Figure

 

1—Wiring diagram for 8KW and 9KW electrified locks (9KW with RQE shown)

Run wires through the door or 

mount wires to the door sur-

face with wire molding.

To find the correct wire gauge 

for wire runs, see Figure

 

2 on 

the reverse side.

RQE

 (Request-to-exit) wires 

are normally used with 

access control systems.

8WDTL

 

Door transfer loop 

Electrified cylindrical 

chassis — 9KW shown 

with RQE

RQE

 (Request-to-exit) wires

Brown 

(common)
Orange 

(NO)
Green 

(NC)

Power Supply

24 Volts AC or DC

*Note

: In some door applications (for 

example fire doors), it may not be 

possible to make extra holes into the 

door. In such scenarios, the TCM may 

be installed in a secure location at no 

more than 20 feet from the door.

Ceiling

Electrical requirements

The following table describes the voltage and current specifications  
for the 8KW and 9KW locks, with RQE (REX) switch, and  
door monitoring switch.

Unit

Voltage

Current

8KW (RQE not avail-
able)

24 volts AC or DC 0.18 amp continu-

ous duty

9KW with and with-
out RQE

24 volts AC or DC 0.18 amp continu-

ous duty

RQE switch

30 volts AC or DC 
maximum

0.7 amp inductive 
0.7 amp resistive

T56090/Rev D    1800760   ER-7991-19   Jan 2015

Wiring Instructions for 8KW and 9KW Series 

Electrified Cylindrical Locks with Request-to-exit 

— Over

TCM

 (Temperature 

Control Module) 
Insert TCM into the 
1“ dia extension.*

(1” dia x 3” deep hole)