15
E
E
E
E
E
A4
BERTAZZONI
A4
BERTAZZONI
A4
BERTAZZONI
STEP-BY-STEP INSTALLATION GUIDE
The Filler Block is only used for recessed cabinet and
front overhang cabinet (see the type of the cabinet on on
pages 8–10). Place the Filler Block to the cabinet bottom
before installing the oven.
5.
Tighten the outer two screws to the top of the microwave
oven. While tightening screws, hold the microwave oven
in place against the wall and the top cabinet.
Cabinet front
Equivalent to
depth of cabinet
recess
Cabinet bottom
Filler block
Cabinet mounting bolt
Microwave oven top
Washer
6.
Install grease filters. See the Use & Care Manual packed
with the microwave.
A5.
ADJUST THE EXHAUST ADAPTER
Open the top cabinet and adjust the exhaust adapter to
connect to the house duct.
Damper
Blower Plate
Back of
microwave
For front-to-back or
side-to-side adjustment,
slide the exhaust
adapter as needed
A6.
CONNECT DUCTWORK
1.
Extend the house duct down to connect to the exhaust
adapter.
2.
Seal exhaust duct joints using duct tape.
House duct
B. OUTSIDE REAR EXHAUST (HORIZONTAL DUCT)
Installation overview
B1. Prepare the Rear Wall Template for outside back exhaust
B2. Attach the mounting plate to the wall
B3. Use Top Cabinet Template for preparation of top cabinet
B4. Adapt microwave blower for outside back exhaust
B5. Mount the microwave oven
B1.
PREPARE THE REAR WALL TEMPLATE FOR
Summary of Contents for KOTR24MXE
Page 22: ......