Technical data
Electrical data
Supply voltage Uv
24 V DC
Voltage range
0,90 ...1,1 Uv
Maximum ripple
≤
5%
Power consumption without peripheral devices
appr. 10 W
Conductor connection
1 x 4,0 mm
2
wire
2 x 1,5 mm
2
wires
Safety Outputs
3 N/O contacts
Switching voltage
24 V DC
Response time (light curtain)
< 20 ms
Input current
appr. 15 mA for each input
Simultaneousness of muting sensors
3 s
Muting time
max. 10 minutes mute over-ride, infinite during normal operation
Startup waiting time
max. 6 s
Switching current, outputs 13-14, 23-24, 33-34
6 A continuous current (one output loaded)
3,5 A continuous current (three outputs loaded)
Output 63-64 (curtain enable)
N/O Relay 2 A / 24 V DC
Output 7374 (auxiliary mute lamp)
N/O Relay 1,2 A / 24 V DC
Output OP-O1, OP-O2
Optocoupler, 20mA /24 V DC
Power supply - muting sensors
Together max. 0,5 A (24 V DC)
Output 53 (muting lamp)
24 V DC, max. 1 A
Mechanical data
Housing material
Self extinguishing according to UL 94 V-0
Dimensions (WxHxD)
90x84x121 mm
Mounting
Snap mounting on universal mounting rail NS35 according to
DIN EN 50022
Environmental data
Environment temperature
-25°C ... +55°C
Humidity
Operation 75% (non condensing), Storage 85% (non condensing)
Creepage and clearance
DIN VDE 0110 part 1 at pollution grade 2, basic isolation: over voltage
category 3; safe breaking: over voltage category 2
Terminal type
IP 20
Housing type
IP 40
Shock resistance
< 0,7 Nm
Vibration resistance
Frequency < 33 Hz, Amplitude < 0,35 mm
beantragt
Mounting rail
DIN EN 50022
90
84
80
113
118
14