5. Fault Finding
In the event of faulty operation, the following procedure is recommended.
•
Check that all moving components are clean and are able to move freely and that they are
free from any obvious damage or wear.
•
If the lift fails to raise:
1.
Check the fuses.
2.
Use a test meter to check that the correct voltage is present at the motor terminals when
the control buttons are operated. If the voltage is low/missing, check back through the
circuit to locate the loss of voltage, usually a loose or dirty connection is the cause (on DC
units- finally, check the condition of the motor brushes and their freedom to move).
•
If the lift fails to lower:
1.
Check the fuses.
2.
Check the voltage at the dump solenoid – if all is OK then the solenoid has probably failed.
If not check back check back through the circuit to locate the loss of voltage.
•
If the table drifts/drops slightly over time:
1.
Visually check for leaks throughout the system (Power pack, ram, hose) (possible seal
failure).
2.
Check dump valve solenoid – could be debris under the seating or a valve failure.
TECHNICAL SPECIFICATIONS
Hydraulic Oil
I.S.O.32 (eg catrol hysol XH)
Capacity
0.9litre (2 pints USA)
Max Hydraulic Pressure
140 Bar (Full Load)
Summary of Contents for EXPRESS DUAL 3000MC
Page 2: ...Bernhard and Company Limited 2 EXPRESS DUAL 3000MC NOTES...
Page 26: ...Bernhard and Company Limited 26 EXPRESS DUAL 3000MC NOTES...
Page 37: ...EXPRESS DUAL 3000MC Bernhard and Company Limited 37 1 2 3 4 5 6 7 8 9 10 11 12 CLAMP ASSEMBLY...
Page 53: ...EXPRESS DUAL LIFT TABLE Bernhard and Company Limited 53 NOTES...
Page 57: ...USER MANUAL ADDENDUM NOTES...