Page 31 of 44
17.07.2014
Ver. 3.3
© Berner Kochsysteme 2015
Observe the installation regulations
Observing installation regulations:
The input air channel is below the unit (option in front or behind) (option with flexible input
air tube).
Under the induction a ground metal (CNS angles) has to be attached, for the Aluminium air
filter. The ground metal must be absolutely removable so that in case of a service the easy
access to the coil or generator is possible. Shouldn't this be possibly in case of special
construction caused other mounting variants must be checked other Solutions. We are ready
to support you in case of other Solutions.
The using of the air filter saves the unit from dirt and grease. Provide the easy exchangeable
of the filter (for weekly cleaning in the dishwasher).
The air outlet carried over the switch face plate. For this the switch face plate need air
outlets.
Optional: the air outlets can be supplied with an air channel. For this, the generators
have to turn around.
The air channel has to be installed, that no water can come inside the unit.
The switch faceplate is not included with the delivery (optionally available).
To provide a proper function, follow the air supply and outlet regulations.
The established frame of the mounting unit has to be sealed up with “Silicone – Pactan®
6076”, preventing around penetrating of liquids.
Broken glass or damage of the glass ceramic hob, please don’t use the unit after this.
Replace the damaged glass ceramic immediately; otherwise there is the danger for
penetrating Liquid into unit. The Liquid leads to damage of the unit.
Installation regulations
The following points have to be follow:
-
Examine and guarantee, that the tension of the main supply agrees with the one of the
type label on the unit.
-
The electrical installations must comply with the local Building installations regulations.
The valid national regulations of the electricity authorities must be followed.
-
The induction-unit is supplied with a Power cord; this can be attached to an electrical
outlet.
-
In case of using an Offset current circuit breaker on the place, use a (FI 30mA).
-
Please prevent to block the air in- and out supply (subjects etc.)
-
Avoid that hot surrounding air is drawn in the unit by around standing equipment like deep
fryers etc.
-
Install the induction unit not in the proximity's of a hot surface or
-
The piece of equipment has a suction filter. You must guarantee, that no fat surroundings
the air-filter, which is caused by other applications (Deep-fryers, grill disks or frying
tippers), can suck into the induction unit.
-
The AIR temperature must be under +35° C.
-
The using staff must take sure, that all Installations- , Maintenance - and Inspection work,
are executed by authorized specialist staff.
-
If more equipment installed in the proximity of the inductive unit, which ones are
regulated electronically? Please, enquire with the manufacturer if troubles are possible, by
the inductive reasoning.
Take account! For the combination: build-in unit with an oven. The switch face plate
has to be closed (no air outlets), to protect the unit from penetration of moisture and
heat.
Summary of Contents for BI1EG2.5B
Page 25: ...Page 24 of 44 17 07 2014 Ver 3 3 Berner Kochsysteme 2015 Generator Views...
Page 26: ...Page 25 of 44 17 07 2014 Ver 3 3 Berner Kochsysteme 2015 Spare Parts List BIPS Generator...
Page 27: ...Page 26 of 44 17 07 2014 Ver 3 3 Berner Kochsysteme 2015 BIPMS Generator...
Page 28: ...Page 27 of 44 17 07 2014 Ver 3 3 Berner Kochsysteme 2015 BIPDS Generator...
Page 29: ...Page 28 of 44 17 07 2014 Ver 3 3 Berner Kochsysteme 2015 BIPDMS Generator...
Page 30: ...Page 29 of 44 17 07 2014 Ver 3 3 Berner Kochsysteme 2015 Displays in different versions...