Installation
Electrical data of the units
Unit performance (3,5 kW-
BIPMS3,5
)
Induction unit 1-phase (Voltage 25% / -10%)
Connection colour
Frequency
Fuse
Phase
Brown, Black or 1
50 Hz / 60 Hz
1 x 16A F
(super quick)
N
Blue
or 2
Working frequency
22-35 kHz
Control fuse
-
PE
Yellow/Green
Unit performance (5 kW-
BIPMS5
)
Induction unit 2-phases (Voltage 45% / -10%)
Connection colour
Frequency
Fuse
Phase
Brown, Black or 1,2
50 Hz / 60 Hz
1 x 16A F
(super quick)
N
Blue
or 4
Working frequency
22-35 kHz
Control fuse
-
PE
Yellow/Green
Unit performance (5 kW, 7kW, 8kW, 9kW-
BIPS
)
Induction unit 3- phases (Voltage 45% / -10%)
Connection colour
Frequency
Fuse
Phase
Brown, Black, Grey or
1, 2, 3
50 Hz / 60 Hz
3 x 16A F
(super quick)
N
Blue
or 4
Working frequency
22-35 kHz
Control fuse
-
PE
Yellow/Green
Unit performance (10 kW-
BIPDS
)
Induction unit 3-phases (Voltage 45% / -10%)
Connection colour
Frequency
Fuse
Phase
Brown, Black, Grey or
1, 2, 3
50 Hz / 60 Hz
3 x 16A F
(super quick)
N
Blue
or 4
Working frequency
22-35 kHz
Control fuse
-
PE
Yellow/Green
Unit performance (3,5 kW-
BIPDMS3,5
)
* Model with power star
Induction unit 1-phasig (Voltage 25% / -10%)
Connection colour
Frequency
Fuse
Phase
Brown, Black or 1
50 Hz / 60 Hz
1 x 16A F
(super quick)
N
Blue
or 2
Working frequency
22-35 kHz
Control fuse
-
PE
Yellow/Green
Function conditions
o
maximum tolerance of the nominal voltage
+5%/-10%
o
frequency
50 / 60 Hz
o
IP CODE (Protection class in delivery state)
IP 11
o
min. Pan-diameter
12 cm
Installations-environment
-
maximum ambient temperature
Storage
>-20°C till +70°C
in Function
>+5°C till +35°C
-
maximum relative Atmospheric humidity
Storage
> 10% till 90%
in Function
> 30% till 90%
Summary of Contents for BI1EG2.5B
Page 25: ...Page 24 of 44 17 07 2014 Ver 3 3 Berner Kochsysteme 2015 Generator Views...
Page 26: ...Page 25 of 44 17 07 2014 Ver 3 3 Berner Kochsysteme 2015 Spare Parts List BIPS Generator...
Page 27: ...Page 26 of 44 17 07 2014 Ver 3 3 Berner Kochsysteme 2015 BIPMS Generator...
Page 28: ...Page 27 of 44 17 07 2014 Ver 3 3 Berner Kochsysteme 2015 BIPDS Generator...
Page 29: ...Page 28 of 44 17 07 2014 Ver 3 3 Berner Kochsysteme 2015 BIPDMS Generator...
Page 30: ...Page 29 of 44 17 07 2014 Ver 3 3 Berner Kochsysteme 2015 Displays in different versions...
Page 44: ...Page 43 of 44 17 07 2014 Ver 3 3 Berner Kochsysteme 2015 Wiring diagram...