TO RESET MANUAL RESET LIMIT
Your heater is equipped with a manual reset safety thermal limit 
control that will automatically turn the heater off to prevent a fire if the
heater  overheats. This  control  is  located  on  the  fan  panel  assembly
between the element and fan blade and marked “reset”. The red reset
button  can  be  seen  through  the  front  grille  when  the  heater  is
installed. To reset, allow the heater to cool, then push the red button
that  is  visible  through  the  hole  in  the  fan  panel.  The  heater  should
immediately return to normal operation.

Once  each  year  the  heater  should  be  cleaned  to  remove  dust  and
other foreign material which has collected during the heating season.
This is a simple operation when performed as follows:
1. Turn off the electric power at main line switch (or remove all 

fuses) to disconnect electric power from the heater. 
THIS IS IMPORTANT.

2. Remove thermostat knob.
3. Remove front cover by depressing plastic snap tabs with a flat 

bladed screw driver as shown in Figure 5. Release both tabs on 
one side then rotate the front cover off of the fan deck.

4. With a vacuum cleaner nozzle or dust cloth, remove dust and 

other foreign material.

5. After cleaning, turn disconnect switch to ON position and reinstall 

the grille.

6. Turn on the main line switch (or replace fuses) to restore power 

to the heater. The heater is now ready for another season of 
operation.

MODEL NO. 

FRA40203

DATE CODE: 

0695

FAN FORCED WALL HEATER
APPAREIL DE CHAUFFAGE MURAL À AIR PLUSÉ
VOLTS AC

60HZ          WATTS        PHASE

HI   LO

208

4800               3

MUST BE USED WITH AWH-BB BACK BOX 
DO NOT OPERATE WITHOUT FRONT COVER IN PLACE.
DOIT ÉTRE UTILISÉ AVEC BOÎTIER ARRIÈRE AWH-BB
NE PAS UTILISER SI LE COUVERCLE AVANT N’EST PAS EN PLACE.
MARLEY ENGINEERED PRODUCTS
BENNETTSVILLE, SC  29512

774G LISTED

ROOM HEATER

DO NOT USE WATER OR DAMP CLOTH FOR CLEANING AND
DO NOT DISTURB THE HEATING ELEMENT.

CAUTION

OPERATION OF THE MANUAL RESET SAFETY THERMAL LIMIT
CONTROL IS  AN  INDICATION  THAT THE  HEATER  HAS  BEEN
SUBJECTED TO SOME ABNORMAL CONDITION. IT IS RECOM-
MENDED THAT THE HEATER BE CHECKED BY A REPUTABLE
ELECTRICIAN OR REPAIR SERVICE TO ENSURE THE HEATER
HAS NOT BEEN DAMAGED.

Fig. 5

!

CAUTION

!

LIMITED WARRANTY

All products manufactured by Marley Engineered Products are 
warranted against defects in workmanship and materials for one year
from date of installation, except heating elements which are warranted
against defects in workmanship and materials for five years from date
of installation. This warranty does not apply to damage from accident,
misuse, or alteration; nor where the connected voltage is more than 5%
above the nameplate voltage; nor to equipment improperly installed or
wired or maintained in violation of the product’s installation instructions.
All claims for warranty work must be accompanied by proof of the date
of installation.

The customer shall be responsible for all costs incurred in the removal 
or reinstallation of products, including labor costs, and shipping costs
incurred  to  return  products  to  Marley  Engineered  Products  Service
Center. Within the limitations of this warranty, inoperative units should
be  returned  to  the  nearest  Marley  authorized  service  center  or  the
Marley Engineered Products Center, and we will repair or replace, at
our option, at no charge to you with return freight paid by Marley. It is
agreed that such repair or replacement is the exclusive remedy avail-
able from Marley Engineered Products.

THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER 
WARRANTIES EXPRESSED OR IMPLIED. AND ALL IMPLIED WAR-
RANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICU-
LAR  PURPOSE  WHICH  EXCEED  THE  AFORESAID  EXPRESSED
WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED FROM
THIS  AGREEMENT. MARLEY ENGINEERED  PRODUCTS  SHALL
NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES ARISING WITH
RESPECT TO  THE  PRODUCT,  WHETHER  BASED  UPON  NEGLI-
GENCE, TORT, STRICT LIABILITY, OR CONTRACT.

Some states do allow the exclusion or limitation of incidental or 
consequential damages, so the above exclusion or limitation may not
apply to you. This warranty gives you specific legal rights, and you may
also have other rights which vary from state to state.

For the address of your nearest authorized service center, contact 
Marley Engineered Products in Bennettsville, SC, at 1-800-642-4328.
Merchandise returned to the factory must be accompanied by a return
authorization and service identification tag, both available from Marley
Engineered Products. When requesting return authorization, include all
catalog numbers shown on the products.

HOW TO ORDER REPAIR PARTS

In order to obtain any needed repair or replacement

parts,  warranty  service  or  technical  information,  please
contact Marley Engineered Products Service Center toll-
free by calling  1-800-642-HEAT. 

When ordering repair parts, always give the informa-

tion listed as follows:

1. The Part Number 
2. The Model Number 
3. The Part Description
4. Date of Manufacture

03-02

Part No. 5200-2302-002   

ECR 35194

SPX Corporation
470 Beauty Spot Rd. East
Bennettsville, SC  29512 USA

Reviews: