background image

b. Remove the “knockout” on the top side of the frame.
c. Remove disconnect switch bracket by loosening the two 

screws on the right side.

d. Feed the power supply cable through the frame allowing 

6" (152mm) of lead to remain inside the back box (using cable 
clamp, connector, or other suitable strain relief).

e. Secure the power supply cable to the back box (using cable 

clamp, connector, or other suitable strain relief) allowing 
6" (152mm) of lead to remain inside the back box.

f. Connect supply wires to blue wires of disconnect switch using 

wiring connectors (see wiring diagram, next page).

g. Ground the back box by connecting the supply ground leadwire 

to the green ground screw located in the inside top of the box.

h. Secure disconnect switch bracket in place.

Installation of Heater Assembly and Grille

After back box is completely installed and no further 
construction  dirt  is  expected,  clean  debris  from  back  box,  remove
heater assembly from its carton, then refer to Figure 4 and proceed
as follows:

1. Insert the heater assembly into back box, placing the four 

mounting holes (with key-hole slots) over the screws in the 
housing. Tighten all screws securely.

2. If surface-mounting frame is used, ensure that the frame is even 

with all four heater assembly tabs before tightening screws.

3. Connect the two disconnected switch wires to the heat-control 

switch (thermostat) leads using wirenuts (see wiring diagram, 
next page).   After connection, push wires back into the 
opening.

4. Turn thermostat to the extreme counterclockwise position.
5. Push disconnect switch into ON position.
6. Install (2) plastic covers on back box as follows: (See Fig. 4)

NOTE:  Both top and bottom plastic covers are identical.

• TOP - Align the screw bosses on the back of the plastic cover 

with the second hole down from the top of the back box and 
attach it with the two screws provided.

• BOTTOM - Align the screw bosses on the back of the other 

plastic cover with holes at the bottom of the back box that are 
just above the fan deck mounting screws and attach it with two 
screws provided.

7. Remount the wire compartment cover.  Install the front cover by 

hooking the (2) tabs on the one side then rotating the front cover 
into place making sure that all four tabs are snapped onto the 
front cover.

8. Fit the thermostat knob onto the thermostat shaft and push into 

place.

Operation

1. Rotate the thermostat fully clockwise. This should energize the 

heating elements and cause warm air to flow from the hot air 
discharge at the openings in the bottom of the grille.

NOTE:  This heater is provided with a fan delay control that allows 
the heating element to warm prior to the fan coming on.  This delay
will also allow the fan to operate for a short period after the heating
element  has  been  turned  off  to  remove  the  residual  heat  from  the
heater.
2. After the operation check, rotate the thermostat to the desired 

position to obtain room comfort.

3. For continuous fan only operation (elements will not be 

energized) rotate thermostat knob where indicator dot on knob is 
aligned with “FAN”.

NOTE: For best results, the heater should be left “ON” 
constantly during the heating season because the thermostat, when
properly set, will maintain the desired temperature.

Fig. 4

THERMOSTAT KNOB

FRONT COVER

PLASTIC
COVER

PLASTIC COVER

POWER LEADS

BACK BOX

INNER FRAME
ASSEMBLY

RECESS WALL
HOUSING

DISCONNECT
SWITCH

THERMOSTAT 

3

MANUAL

RESET

LIMIT

DISCONNECT

L1

L2 or N

ELEMENT

ELEMENT

F.D.

FAN MOTOR

T-STAT

L1 OFF

CYC

L2

DISCONNECT

L1

L2 or N

F.D.

L1 OFF

CYC

L2

FAN MOTOR

MANUAL

RESET

LIMIT

ELEMENT

T-STAT

FAN MOTOR

MANUAL

RESET

LIMIT

T-STAT

L1 OFF

CYC

L2

DISCONNECT

L1

L2 or N

F.D.

SEC

PRI

ELEMENT

ELEMENT

4800, 4000, & 3000 WATT HEATERS

208V, 240V, OR 277V  (Full wattage heaters can be converted to half
wattage by removing the red jumper wire connecting the top and bot-
tom element terminals.) 

4800, 4000, & 3000 WATT HEATERS

347V, 600V

2000 & 1500 WATT HEATERS

208V, 240V, OR

277V  

WIRING DIAGRAMS (ALL 1Ø)

ELEMENTS

FAN

MOTOR

FAN

DELAY

RELAY

FIELD WIRING

GND

THERMOSTAT

MANUAL

RESET

1

6

8

4

6

2

WIRING DIAGRAM

FOR THREE PHASE WALL HEATERS

CYC

L1

L2

OFF

DISCONNECT

ELEMENTS

FIELD WIRING

GND

WIRING DIAGRAM

4800 WATT 208 VOLT

SINGLE PHASE WALL HEATER

DISCONNECT

FAN

MOTOR

FAN

DELAY

MANUAL

RESET

RELAY

1

0

8

4

6

2

CYC

L1

L2

OFF

WIRING DIAGRAMS (ALL 1Ø)

Reviews: