Help in case of trouble
GB
Cause 4: automatic running time detection is activated, but the
switching voltage is < 230 V or drives with electronic
limit switches are being used.
Deactivate the automatic running time detection.
Correct the electrical connection and remove the N conductor.
Blind/shutter does not move to limit position, positioning or
scene moves faulty
Cause: blind/shutter running time adjustment incorrect.
Correct the blind/shutter running time.
Blind/shutter moves upward before a positioning scene
moves
Cause: No position stored, e.g. because of mains failure.
Blind/shutter performs a reference run. Do not stop the moving
blind/shutter.
Accessories
Isolating relay UP/AP
Order no. 2930
Isolating relay REG
Order no. 2931