Information for qualified electricians
The automatic running time detection cannot be used for 110 V
AC drives, for DC drives, for drives with electronic limit switches
and for drives connected to the outputs via isolating relays.
Only for 230 AC drives with mechanical limit switches.
The running time detection function is activated in the software.
The blinds/shutters are not blocked.
Connect the bus line to the bus terminal (Fig. 3).
Connect the mains voltage supply (Fig. 3).
Connect only one drive to an output.
Observe the admissible load rating (Technical data).
Connect the drive (Fig. 5).
Connect the N conductor of the respective drive to the N conduc-
tor terminals (Fig. 5, 14) Observe the RCD wiring.
Tick
230 V
operation on the label (Fig. 5).
The N conductor terminals of the individual outputs and of the
mains connection are internally not connected.