Berkeley HL series Owner'S Manual Download Page 3

Table of Contents

3

Page

General Safety .....................................................................................................2

Warranty ..............................................................................................................3

Typical Installations..............................................................................................4

Discharge Pipe and Pressure Tank Connections ...................................................5

Electrical ..............................................................................................................6

Preparing To Start The Pump – Deep Well ...........................................................7

Preparing To Start The Pump – Shallow Well  ......................................................8

Repair Parts  .....................................................................................................8-9

Troubleshooting..................................................................................................10

Berkeley/Wicor Canada Company (“Wicor”) warrants to the original
consumer purchaser (“Purchaser”) of its products that they are free
from defects in material or workmanship.

If within twelve (12) months from the date of installation or twenty-
four (24) months from the date of manufacture any such product shall
prove to be defective, it shall be repaired or replaced at
Berkeley’s/Wicor’s option, subject to the terms and conditions set
forth below.

General Terms and Conditions

Purchaser must pay all labor and shipping charges necessary to
replace product covered by this warranty. This warranty shall not
apply to products which, in the sole judgement of Berkeley/Wicor,
have been subject to negligence, abuse, accident, misapplication, tam-
pering, alteration; nor due to improper installation, operation, main-
tenance or storage; nor to other than normal application, use or ser-
vice, including but not limited to, operational failures caused by cor-
rosion, rust or other foreign materials in the system, or operation at
pressures in excess of recommended maximums.

Requests for service under this warranty shall be made by contacting
the installing Berkeley/Wicor dealer as soon as possible after the dis-
covery of any alleged defect. Berkeley/Wicor will subsequently take

corrective action as promptly as reasonably possible. No requests for
service under this warranty will be accepted if received more than 30
days after the term of the warranty.

The warranty on all three phase submersible motors is void if three-
leg overload protection of recommended size is not used.

This warranty sets forth Berkeley’s/Wicor’s sole obligation and pur-
chaser’s exclusive remedy for defective products.

BERKELEY/WICOR SHALL NOT BE LIABLE FOR ANY CONSE-
QUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHAT-
SOEVER.

THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU
OF ALL OTHER EXPRESS WARRANTIES. IMPLIED WARRANTIES,
INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES
OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PUR-
POSE, SHALL NOT EXTEND BEYOND THE DURATION OF THE
APPLICABLE EXPRESS WARRANTIES PROVIDED HEREIN.

Some states do not allow the exclusion or limitation of incidental or
consequential damages or limitations on how long an implied war-
ranty lasts, so the above limitations or exclusions may not apply to
you.This warranty gives you specific legal rights and you may also have
other rights which vary from state to state.

Berkeley Limited Warranty

In the U.S.: Berkeley, 293 Wright St., Delavan, WI 53115

In Canada: Wicor Canada Company, 1800 Courtney Park Drive East, Unit 5-7, Mississauga, Ontario L5T 1W1

Wicor Canada Company, 200-E, Rue St-Louis, St-Jean-Sur-Richelieu, Québec J3B 1Y1

ATTACH ORIGINAL RECEIPT HERE FOR WARRANTY CONSIDERATION.

Summary of Contents for HL series

Page 1: ...ation Operation Parts For further operating installation or maintenance assistance Call 1 800 363 PUMP 7867 PRINTED IN U S A BE423 Rev 3 18 98 20 40 60 80 100 2434 0497SR HL and SL Series 1800 Courtne...

Page 2: ...ouch an operating motor Modern motors are designed to operate at high temperatures To avoid burns when servicing pump allow it to cool for 20 minutes after shut down before handling Do not allow pump...

Page 3: ...ing Berkeley Wicor dealer as soon as possible after the dis covery of any alleged defect Berkeley Wicor will subsequently take corrective action as promptly as reasonably possible No requests for serv...

Page 4: ...0 60 80 10 0 Priming Tee and Plug Drive Coupling Drive Point Check Valve Drive point below water level Pressure Gauge Priming Tee and Plug Well Casing Foot Valve Sanitary Well Seal Suction Pipe From W...

Page 5: ...f pass ing the entire pump capacity at 75 PSI pressure Connect the Air Volume Control AVC tube to the 1 8 NPT AVC port on the pump body Run the tubing from the pump s AVC port to the AVC mounted on th...

Page 6: ...re 8 Figure 8 Motor wiring connections through Pressure Switch Match motor voltage to line voltage Your Motor Terminal Board under the motor end cover and Pressure Switch look like one of those shown...

Page 7: ...11 and let the pressure drop until the pressure gauge needle starts to flutter When the needle flutters close the valve just enough to stop the flutter see Figure 11 Your pump is now operating at its...

Page 8: ...alve open in a shallow well installation the control valve always stays open Step 3 Power on Start the pump The pump should pump water in two or three minutes Step 4 If you don t have water after 2 or...

Page 9: ...t Key Part 5SL 7SL 10SL 15SL No Description Qty 1 2 HP 3 4 HP 1 HP 1 1 2 HP 1 Motor 1 A100CLL A100DLL A100ELL A100FLL 2 Water Slinger 1 C69 2 C69 2 C69 2 C69 2 3 Seal Plate 1 N3 9 N3 9 L3 10 L3 10 4 S...