10
EXCLUSIVE
MINIMUM
VALUE
MAXIMUM
VALUE
ACCESS LEVEL
NOTES
SET
VALUE
PARAMETERS
INSTALLER
TIMER OFF CH
3 min
0 min
20 min
INSTALLER
HYST ON HIGH TEMP
5°C
2°C
10°C
SERVICE
HYST OFF HIGH TEMP
5°C
2°C
10°C
SERVICE
HYST ON LOW TEMP
3°C
2°C
10°C
SERVICE
HYST OFF LOW TEMP
3°C
2°C
10°C
SERVICE
SP INCR HIGH TEMP
5°C
0°C
10°C
SERVICE
SP INCR LOW TEMP
0°C
0°C
6°C
SERVICE
INCR COOLING SP
0°C
0°C
10°C
SERVICE
PUMP DUTY CYCLE
85
41
100
SERVICE
RESET TIMERS CH
FUNC. NOT ACTIVE
FUNC. NOT ACTIVE
FUNCTION ACTIVE
INSTALLER
DHW THERMOSTAT
RELATED
RELATED
ABSOLUTE
INSTALLER
Only in instantaneous configuration
SLIDING OUTLET
DEACTIVATE FUNC.
DEACTIVATE FUNC.
ACTIVATE FUNCTION
INSTALLER
CH DELAY POST-DHW
0
0
1
SERVICE
CH DELAY TIME
6sec
1sec
255sec
SERVICE
If CH DELAY POST-DHW = 1
PRESS TRANSDUCER
1
0
1
SERVICE
LOAD ENABLE
0
0
1
SERVICE
Only if PRESS TRANSDUCER = 1
START LOADING VALUE
0,6
0,4
1
SERVICE
Only if
LOAD ENABLE = 1
PREHEATING
0
0
1
INSTALLER
Only if managed by the control board
THERMOREGULATION
INSTALLER
CLIMATIC CURVES
MAIN
MAIN / ZONE1 / ZONE2
INSTALLER
FIXED SET POINT
80,5 °C (AT)
45 °C (BT)
MIN CH SET
MAX CH SET
INSTALLER
If EXTERNAL PROBE NOT connected
NIGHT COMP
FUNC. NOT ACTIVE
FUNC. NOT ACTIVE
FUNCTION ACTIVE
INSTALLER
If EXTERNAL PROBE connected
CURVE SLOPE
2,0
1,0
3,0
INSTALLER
If EXTERNAL PROBE connected,
request type TA and zone type AT
0,4
0,2
0,8
INSTALLER
If EXTERNAL PROBE connected,
request type TA and zone type BT
2,0
0,1
5,0
INSTALLER
If request type AMBIENT PROBE
or REC10
AMBIENT INFLUENCE
10
0
20
INSTALLER
If request type AMBIENT PROBE
or REC10
OFFSET
20°C
20°C
40°C
INSTALLER
If request type AMBIENT PROBE
or REC10
COOLING
18°C
4°C
20°C
INSTALLER
BUILDING TYPE
5min
5min
20min
INSTALLER
Only if EXTERNAL PROBE connected
OUTDOOR REACTIVITY
20
0
255
INSTALLER
Only if EXTERNAL PROBE connected
RANGE RATED
MAX CH
MIN
MAX CH
INSTALLER
CALIBRATION
INSTALLER
MIN
INSTALLER
MAX
INSTALLER
RLA
MIN
MAX
INSTALLER
MAX CH
MIN
MAX
INSTALLER
DEFAULT VALUE
FACTORY SET
see MULTIGAS TABLE
see MULTIGAS TABLE
see MULTIGAS TABLE
see MULTIGAS TABLE
1500 RPM
3000 RPM
5500 RPM
9999 RPM