29
English
If the CO
2
proves to comply with the values in the table,
proceed to adjust the next parameter (LL - adjusting the
minimum), if different modify the value by turning the
maximum power adjustment screw with a screwdriver
(clockwise to decrease) until you obtain a value contained
in
table 1
.
MINIMUM POWER ADJUSTMENT - LL
- Select the parameter LL (with the boiler still OFF) and
wait for the boiler to come on.
- Check that the minimum CO
2
reading on the analyser
(see paragraph “Checking combustion parameters”, page
31) corresponds with the values indicated in
table 2
.
If the CO
2
proves to be different from the values in the
table, proceed to adjust the parameter by turning the
maximum power adjustment screw after having
unscrewed the protective cap (clockwise to increase) until
you obtain a value contained in
table 2.
IGNITION SPEED (P.MM)
- Select parameter MM.
The boiler starts at the slow ignition speed.
- Turn the heating water selector to increase or decrease
the ventilator speed.
MAXIMUM ELECTRIC HEATING ADJUSTMENT - 23
-
Select parameter 23
- Press the ENTER button to access the parameter value
modification function
- Turn the sanitary water selector to modify the maximum
ventilator speed,
table 3
- Confirm the value you have set by pressing ENTER.
MINIMUM ELECTRIC HEATING ADJUSTMENT - 24
- Select parameter 24
- Press the ENTER button to access the parameter value
modification function,
table 4
table 4
table 4
table 4
table 4
- Turn the sanitary water selector to modify the minimum
ventilator speed
- Confirm the value you have set by pressing ENTER.
MAXIMUM VENTILATOR SPEED (P. HP)
- Select parameter HP
- Press the ENTER button, then modify the value of the
parameter by turning the sanitary water temperature
selector. The maximum speed of the ventilator is linked
with the type of gas and the power of the boiler
- Turn the sanitary water temperature selector in order to
adjust the set value
- Confirm the new value you have set by pressing
ENTER.
The value indicated on the display is expressed in revs
min/100 (example 3600 = 36).
The value set during this operation automatically modifies
the maximum value of parameter 23.
MINIMUM VENTILATOR SPEED (P. LP)
- Select parameter LP
- Press the ENTER button, then modify the value of the
parameter by turning the sanitary water temperature
selector. The minimum speed of the ventilator is linked
with the type of gas and the power of the boiler
- Turn the sanitary water temperature selector in order to
adjust the set value
- Confirm the new value you have set by pressing
ENTER.
The value indicated on the display is expressed in revs
min/100 (example 3600 = 36).
The value set during this operation automatically modifies
the maximum value of parameter 24.
VENTILA
VENTILA
VENTILA
VENTILA
VENTILAT
T
T
T
TOR IGNITION SPEED (P
OR IGNITION SPEED (P
OR IGNITION SPEED (P
OR IGNITION SPEED (P
OR IGNITION SPEED (P..... SP)
SP)
SP)
SP)
SP)
- Select parameter SP
- Press the ENTER button, then modify the value of the
parameter by turning the sanitary water temperature
selector. The standard slow start value is 3700 revs/
min
- Confirm the new value you have set by pressing
ENTER.
MAXIMUM POWER ADJUSTMENT - HH
- Turn the boiler OFF
- Select the parameter HH and wait for the boiler to come
on
- Check that the maximum CO
2
reading on the analyser
(see paragraph “Checking combustion parameters”, page
31) corresponds with the values indicated in
table 1
.
Minimum power
adjusting screw
Maximum power
adjusting screw
25 C.S.I.
CO
2
max
9,0
10,0
%
35 C.S.I.
CO
2
max
9,0
10,0
%
16 R.S.I.
CO
2
max
8,8
10,0
%
35 R.S.I.
CO
2
max
9,0
10,0
%
DESCRIPTION
tabel 1
G31
G20
25 C.S.I.
CO
2
min
9,3
10,3
%
35 C.S.I.
CO
2
min
9,0
10,0
%
16 R.S.I.
CO
2
min
8,8
10,0
%
35 R.S.I.
CO
2
min
9,0
10,0
%
DESCRIPTION
tabel 2
G31
G20
25 C.S.I.
49
51
revs/min
35 C.S.I.
60
60
revs/min
16 R.S.I.
48
48
revs/min
35 R.S.I.
60
60
revs/min
MAXIMUM NUMBER OF
VENTILATORE REVOLUTIONS
tabel 3
G31
G20
25 C.S.I.
14
14
revs/min
35 C.S.I.
14
14
revs/min
16 R.S.I.
14
14
revs/min
35 R.S.I.
14
14
revs/min
MINIMUM NUMBER OF
VENTILATORE REVOLUTIONS
tabel 4
G31
G20
Fig. 51