background image

 EN 

.

 

 

2

 

 

T

HIS INSTRUCTIONS TO BE RETAINED BY THE USER

 

 

Thank  you  for  choosing  this  thermostat.  This  central  heating 
control  device  is  easy  to  fit,  and  with  correct  use,  will  deliver 
improved  comfort  levels  in  your  home  whilst  saving  you 
money. 
This  thermostat  is  designed  to  be  used  only  with  heating 
controls  system  with  a  maximum  switching  load  of  2A  at 
30VDC or 0,25A at 230VAC. 
If  installing  for  someone  else,  please  ensure  that  the 
instructions are handed to the householder. 
W

ARNING

: Please read this manual prior to installation or use. 

S

HOCK 

H

AZARD

:  This  unit  must  be  installed  by  a  competent 

person,  in  accordance  with  BS  7671  (the  IEE  Wiring 
Regulations), or other relevant national regulations and codes 
of  good  practice.  Always  isolate  the  AC  Mains  supply  before 
installing this unit. 
 

FIRST INSTALLATION WARNING

. 

The  product  arrives  with  most  of  the  parameters

 

factory  set 

with  minimal  actions  required  by  the  installer:  wiring 
connections  of  the  receiver  to  the  boiler,  setting  the  time  and 
setting  the  day.  All  the  rest,  like  heating  pattern,  default 
temperatures, etc. are already pre-configured at the factory. 
 
I

MPORTANT

:  these  instructions  should  be  read  in  conjunction 

with  the  appliance installation instructions.  It is  recommended 
that this device is installed by a qualified electrician. 

E

NCODER 

KNOB

:

 

Encoder 

movements: 

clockwise and anticlockwise rotation, push to 
select. 
Encoder  clockwise  and  anticlockwise 
rotation:  
increase  or  decrease  the  room 
comfort temperature, press to enter. 

Encoder  rotation  one  step:  check  the  selected  comfort 
temperature. The value will blink for few times and later it will 
be back to the room temperature value display. 
Press  and  hold  the  encoder  once  to  activate  or  de-activate 
the ADVANCE function 
Press  and  hold  the  encoder  longer  for  enter  in  menu  and 
select 

the 

status 

mode 

or 

set 

the 

time/programming/parameters (see specific paragraph). 
 
 
 
 
 
 
 
 
 
 
 

L

CD 

D

ISPLAY

 

 

 

 

D

ISPLAY

 

E

NCODER

 

S

ENSOR

 

O

PENING

 

Summary of Contents for Alpha 7D

Page 1: ...WIRED manual issue 12 2012 rev 00 WEEKLY ROOM THERMOSTAT Installation and user instruction page 2 EN CRONOTERMOSTATO SETTIMANALE Manuale di installazione e uso pag 8 IT...

Page 2: ...rs factory set with minimal actions required by the installer wiring connections of the receiver to the boiler setting the time and setting the day All the rest like heating pattern default temperatur...

Page 3: ...election only for expertise Escape from main menu QUICK START GUIDE To be read and used after a proper installation has been made and after the hours and the working mode has been set WORKING MODE Thi...

Page 4: ...on temperature selection 03 hysteresis OFF value selection 04 hysteresis ON value selection 05 encoding and coupling with the RF receiver 06 radio frequency value selection EHIt escape from technical...

Page 5: ...uch the printed circuit board of the transmitter as it contains electrostatically sensitive components FUNCTIONS The weekly thermostat has the following functions Room thermostat the internal temperat...

Page 6: ...target Hysteresis ON 0 2 C boiler switch ON at 0 2 C be low the target LOW BATTERIES The two supplied batteries will last for approximately 2 years under a normal usage When the batteries are low the...

Page 7: ...ting is 5 C the 03 parameter can be adjusted between 3 C and 10 C the frost protection selected temperature becomes the minimum settable value for the economy temperature inside the main menu WARNING...

Page 8: ...IONE PER L INSTALLATORE Il prodotto arriva gi impostato dalla fabbrica nella maggior parte dei sui parametri il minimo richiesto alla prima installazione l impostazione dell ora e del giorno della set...

Page 9: ...dalle 16 00 alle 18 59 Temperatura ambiente Batterie scariche Richiesta di calore verso la caldaia attiva riscaldamento acceso Sono inoltre presenti all interno del men utente altre icone di seguito...

Page 10: ...nferma di una delle tre modalit di stato del cronotermostato fa uscire automaticamente dal men utente Temperatura Economy ECOt Ruotare per selezionare la temperatura di economy e premere per confermar...

Page 11: ...fo specifiche tecniche La non compatibilit comporta un mal funzionamento e pericolosit dell installazione Vedi immagine successiva per una installazione tipica La posizione dei due fili rispetto ai mo...

Page 12: ...pento giorno per giorno a step di un ora La programmazione possibile su di un arco temporale settimanale 7 giorni Modalit di stato sono selezionabili AUTO PARTY e OFF Selezionare la modalit AUTO se si...

Page 13: ...il riscaldamento viene spen to a 0 4 C al di sopra del target impostato Isteresi ON 0 2 C il riscaldamento viene acces o a 0 2 C sotto il target impostato BATTERIE SCARICHE Le due batterie in dotazio...

Page 14: ...ndersi n come antigelo principale dell impianto di riscaldamento n come protezione della caldaia 03 ISTERESI OFF Il valore selezionato con questo parametro indica l isteresi di spegnimento della richi...

Reviews: