background image

4

GENERAL

1  GENERAL SAFETY INFORMATION

Check that the product is complete, undamaged and 

as ordered as soon as you receive it. Report any dis-

crepancies or damage to the 

B

 dealer who sold it.

This  product  must  be  installed  by  a  legally  qualified 

heating  engineer.  On  completion  of  the  installation, 

the installer must issue the owner with a declaration 

of conformity confirming that the installation has been 

completed to the highest standards in compliance with 

the instructions provided by 

B

 in this instruction 

manual, and that it conforms to all applicable laws and 

standards.

This product must only be used for the purpose for 

which it is designed and made, as specified by 

B

B

 declines all responsibility, contractual or other, 

for damage to property or injury to persons or animals 

caused by improper installation, adjustment, mainte-

nance or use.

The product must be serviced at least once a year. 

Servicing must be arranged in advance with the 

B

 

Technical Assistance Centre.

All servicing and repairs must be performed by a quali-

fied heating engineer.

If water leaks from the storage cylinder, turn off the wa-

ter supply and contact 

B

’s Technical Assistance 

Centre or a qualified heating engineer immediately.

If the product is not going to be used for an extended 

period of time, contact the manufacturer’s Technical 

Assistance Centre to have at least the following oper-

ations performed:

- Close  the  shut-off  cocks  for  the  domestic  hot  water 

circuit

- Shut down the boiler connected to the storage cylin-

der as instructed in its own manual

- Switch the storage cylinder OFF at the control panel (if 

fitted) and at the mains power switch

- Drain the central heating circuit and domestic hot wa-

ter circuit if there is any risk of freezing.

This instruction manual is an integral part of the prod-

uct.  It  must  be  kept  safe  and  must  ALWAYS  accom-

pany the product, even if it is sold to another owner or 

transferred to another user or to another installation. If 

you lose this manual, order a replacement immediately. 

Keep the product purchase documents to be present-

ed to the 

B

 authorised Technical Assistance Centre 

to request a service call under warranty.

Size the solar expansion tank so as to ensure complete 

absorption of the expansion of the fluid contained within 

the system, with reference to the prevailing regulations 

on  the  matter.  In  particular,  consider  fluid  character-

istics, considerable fluctuation of service temperature 

and vapour that might be generated during solar col-

lector stagnation stage. Proper size of expansion tank 

ensures setting off of all volume changes of the heat 

transfer  fluid,  avoiding  excessive  pressure  increase. 

Limited pressure changes avoid reaching safety valve 

opening pressure and the consequent fluid drainage.

2  PRECAUTIONS

The operation of any appliance that uses electrical power 

demands that a number of fundamental safety precautions 

be respected. In particular:

Never attempt to install the system without using suit-

able personal protection equipment and without fol-

lowing all applicable occupational safety standards.

Do not touch the product when barefoot or wet if it 

has any electrical accessories installed in it.

Never clean or service the storage cylinder without 

first turning the mains power switch OFF to discon-

nect all electrical accessories (if fitted) from the mains 

electricity supply.

Never pull, disconnect, or twist any electrical cables 

coming from the appliance even if it is disconnected 

from the mains electricity supply.

Do not expose the storage cylinder to the elements. It 

is not designed for use outdoors.

If solar plant pressure decreases, it is forbidden to 

top up with only water as there is a danger of freezing 

and overheating.

Do not use connections or safety devices or fittings 

(expansion vessels, pipes, insulation) that are not 

specifically designed and tested for use in solar wa-

ter heating systems.

Do not allow children or infirm persons to operate the 

system unsupervised.

Do not dispose of packaging material into the envi-

ronment, or leave it within the reach of children, since 

it can become a potential hazard. Dispose of packag-

ing material in compliance with applicable legislation.

General

Summary of Contents for 20086803

Page 1: ...Installation and Operation Manual Solar solar storage cylinder IDRA N DS Installation and Operation Manual EN...

Page 2: ...2...

Page 3: ...following symbols are used in this manual b CAUTION Identifies actions that require caution and adequate preparation a STOP Identifies actions that you MUST NOT do This manual Code Rev comprises pages...

Page 4: ...acement immediately Keep the product purchase documents to be present ed to the B authorised Technical Assistance Centre to request a service call under warranty b Size the solar expansion tank so as...

Page 5: ...t 20052790K4LH3800001 Model IDRA N DS 1500 Code 20052790 Serial Number K4LH3800001 Beretta Caldaie Via Risorgimento 13 23900 Lecco LC Italy Capacit nom sanitaria 1449 L 1 8 mq 3 4 mq 1200 L h 2200 L h...

Page 6: ...Sleeve for electric heating element 1 1 2 Coil water capacity 19 4 28 1 28 4 L Coil heat exchange surface area 3 4 4 6 4 6 m2 Power absorbed by coil 88 120 110 kW Domestic hot water production 2200 29...

Page 7: ...ders are equipped with ded icated sockets for the storage cylinder TEMPERATURE GAUGE or TEMPERATURE SENSOR b The installer is responsible for making all necessary connections to the boiler and solar c...

Page 8: ...1 2 F 1 1 4 F Psc1 Diameter length of boiler sensor socket 8 200 mm Psc2 Diameter length of boiler sensor socket 8 200 mm Psr Diameter length of solar controller sensor socket 8 200 mm RE Sleeve for e...

Page 9: ...it safe MODELS IDRA N DS 2000 B IDRA N DS storage cylinders come in two separate packages The first contains the painted cylinder protected by a plastic bag and supported on a wooden pallet The secon...

Page 10: ...equipment and use suitable safety devices b Make sure that any lifting equipment is of adequate capacity to lift and move the storage cylinder a Do not dispose of packaging material into the envi ron...

Page 11: ...storage cylinder from the pallet cut the straps secure the lifting cables to the lifting points on the top of the storage cylinder carefully lift the storage cylinder and position it as re quired 11...

Page 12: ...npack all the material from the second package Wrap the insulation 3 around the storage cylinder carefully lining up the fittings with the holes on the inside of the insulation Secure the insulation i...

Page 13: ...orage cylinder is to be installed 14 INSTALLATION IN OLDER SYSTEMS AND SYSTEMS REQUIRING MODERNISATION When installing B IDRA N DS storage cylinders in old systems or systems requiring modernisation a...

Page 14: ...ake sure that all circuits have been bled Make sure that the boiler and solar collectors con nected to the system shut down correctly when their mains power switches are turned OFF Provided the above...

Page 15: ...e cylinder after cleaning it a Do not use abrasive products petrol or triethylene INTERNAL CLEANING Removing and checking the magnesium anode Remove the cap 1 cover 2 and the anode insula tor disc 1 2...

Page 16: ...functioning Check the pump The water temperature from the boiler is too low Check the temperature setting There is air in the primary circuit Bleed the circuit SOLAR COLLECTOR CIRCUIT FAULT CAUSE SOLU...

Page 17: ...the environmental impact and save energy in case of brief absences week ends short trips etc and with external temperatures above 0 C set the heater tem perature control where available to the minimu...

Page 18: ...END USER 18...

Page 19: ...END USER 19...

Page 20: ...23 A 23900 Lecco LC www berettaboilers com The manufacturer strives to continuously improve all products Appearance dimensions technical specifications standard equipment and accessories are therefor...

Reviews: