85
Installation
6005770_a – 07.04.2021
EN
3.5.5
Connect the device from inside – BMK-F or
BMK-Z variant
There are two options for laying the control cable to the
cooker hood:
y
In the exhaust air duct to the cooker hood and then
through an outlet from the exhaust air duct.
y
Directly on the wall through an outlet from the exhaust
air duct and then parallel to the cooker hood.
Ø 14
☞
Drill an outlet for the connection cable from the wall
power supply in the exhaust air duct.
☞
Also drill an outlet for the control cable in the exhaust air
duct.
☞
Feed the cable through a grommet and the relevant
outlet in the exhaust air duct to the device.
To ensure that dismounting the drive unit is possible:
☞
Lay the connection cable and the control cable so that
there is a loop of approx. 250 mm in the exhaust air duct.
☞
Seal the outlets with the grommet.
☞
Connect the connection cable from the wall power
supply and the control cable to the device.
☞
Connect the control cable to the cooker hood.
For information on connecting the control line, see the
cooker hood’s instructions.
☞
Connect the exhaust air duct to the device’s inside wall.
☞
Plug the wall power supply’s plug into the socket.
The device is ready for operation.